13 I Pool Heat Pump

Performance Specifications

Model
Heating Capacity
KW
Air
Heating Input
KW
15°C
/Water
Normal Current
A
26°C
Cop
Power Supply
V/Ph/Hz 230V/1Ph/50Hz 230V/1Ph/50Hz 230V/1Ph/50Hz
Setting Temp. Range
°C
Running Temp. Range
°C
Titanium PVC
Water Heat Exchanger
Compressor
Compressor Quantity
Fan quantity
Hydraulic Connection
MM
Min/Max Water Flow Rate
LPM
Sound Pressure Level at 1M
dB(A)
Sound Pressure Level at 10M
dB(A)
Unit Dimentions(L*W*H)
MM
810 x 880 x 1075 810 x 880 x 1075 810 x 880 x 1075
Net Weight
Kg
Refrigerant
Display
Mode
Cooling/Auto
Electroheat
Electroheat
Electroheat
ECO V
ECO V
ECO V
17kW
21kW
25kW
17.2~4.6
21.0~5.1
24.1~6.1
4.05~0.62
5.0~0.69
5.95~0.85
17.6~2.70
21.7~3.0
27.2~3.95
4.25~7.45
4.20~7.4
4.05~7.2
15°C~40°C /
15°C~40°C /
15°C~40°C /
59°F~104°F
59°F~104°F
59°F~104°F
-10°C~43°C /
-10°C~43°C /
-10°C~43°C /
14°F~109.4°F
14°F~109.4°F
14°F~109.4°F
Titanium PVC
Titanium PVC
Tank
Tank
Tank
Inverter
Inverter
Inverter
1
1
1
1
1
1
50 PVC SLIP
50 PVC SLIP
50 PVC SLIP
110 - 160
135 - 185
145 - 195
50~59
50~59
50~59
32~42
32~42
32~42
118
120
122
R410A
R410A
R410A
LCD
LCD
LCD
Heating/
Heating/
Heating/
Cooling/Auto
Cooling/Auto

OPERATION OF YOUR POOL HEAT PUMP

Initial Heating

To achieve initial heating, your pool heat pump and the pool pump may require
extended operation until desired temperature is achieved. The initial heating time
may vary depending upon the five factors listed below. After initial heating, operating
time may be reduced to match daily heat loss.
1.
Size of the pool.
2. How many degrees the water is to be heated.
3. Ambient air temperature - the warmer the air, the less time required to heat.
4. use of a solar blanket.
5. The size of the pool heat pump.
Waterco recommend atmospheric conditions as well as the pool water temperature
should not be below the minimum operating temperatures as stated below in order
to obtain efficiency and avoid codes from appearing on the electronic control
temperature display ; these codes are not generally an issue with the pool heat pump
at these conditions and is not covered by the warranty.
If a combination of the atmospheric and water temperatures are below the minimum
listed concurrently the pool heat pump should not be operated and be switched off.
Generally, atmospheric conditions (air temperature) will be warmer during day time
hours. To accelerate the initial heating period owners may opt to increase the ambient
air temperature artificially around the evaporator area of the pool heat pump until the
pool water temperature has reached the minimum required as stated below.
Atmospheric conditions
Model
must be above
electroheat eCO-V
0°C / 32°F

Adjustment Of The Bypass Valves

Waterco eCO-V pool heat pumps do not require the water by pass valves adjusted
to cope with cooler water temperatures. In the event of low water temperatures, the
eCO - V inverter pool heat pumps increase the operating frequency of the compressor
which in turn increases the output capacity of the unit.
It is essential water flow through the unit is within the range specified in the
Performance Specifications table opposite. The bypass valve may be used to tune
the water flow within range.
The adjustment may vary according to pool pump size.
Pool Heat Pump I 14
Pool water temperature
must be above
10°C / 50°F