Waterco ELECTROHEAT ECO-VS MPC110WAT Installation And Operation Manual

Waterco ELECTROHEAT ECO-VS MPC110WAT Installation And Operation Manual

Waterco pool heat pump
Table of Contents

Advertisement

Quick Links

OFFICES - AUSTRALIA
OFFICES - OVERSEAS
NSW - SYDNEY
WATERCO (EUROPE) LIMITED
(HEAD OFFICE)
SITTINGBOURNE, KENT. UK
TEL: +61 2 9898 8600
TEL: +44 (0) 1795 521 733
QLD - BRISBANE
WATERCO (USA) INC
TEL: +61 7 3299 9900
AUGUSTA, GEORGIA, USA
TEL: +1 706 793 7291
VIC/TAS - MELBOURNE
TEL: +61 3 9764 1211
WATERCO CANADA
BOUCHERVILLE, QUEBEC,
WA - PERTH
CANADA
TEL: +61 8 9273 1900
TEL: +1 450 748 1421
SA/NT - ADELAIDE
WATERCO (NZ) LIMITED
TEL: +61 8 8244 6000
AUCKLAND, NEW ZEALAND
TEL: +64 9 525 7570
ACT DISTRIBUTION
TEL: +61 2 6280 6476
WATERCO (C) LIMITED
GUANGZHOU, CHINA
TEL: +86 20 3222 2180
Waterco Limited ABN 62 002 070 733
Waterco Limited ABN 62 002 070 733
(ZZM1836) 09/2024
WATERCO (FAR EAST) SDN BHD
SELANGOR, MALAYSIA
TEL: +60 3 6145 6000
PT WATERCO INDONESIA
JAKARTA, INDONESIA
TEL: +62 21 4585 1481
WATERCO INTERNATIONAL PTE LTD
MIDVIEW CITY, SINGAPORE
PH: +65 6344 2378
WATERCO VIETNAM COMPANY LIMITED
HO CHI MINH CITY, VIETNAM
TEL: +84 28 3622 7780
WATERCO POOL HEAT PUMP
Installation and
Operation Manual
This equipment must be installed and serviced by a qualified technician.
!
WARNING
Improper installation can create electrical hazards which could result in property
damage, serious injury or death. Improper installation will void the warranty.
Notice to Installer
This manual contains important information about the installation, operation and
safe use of this product. Once the product has been installed this manual must
be given to the owner/operator of this equipment.
ECO-VS
www.waterco.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELECTROHEAT ECO-VS MPC110WAT and is the answer not in the manual?

Questions and answers

Summary of Contents for Waterco ELECTROHEAT ECO-VS MPC110WAT

  • Page 1 TEL: +61 2 6280 6476 WATERCO (C) LIMITED GUANGZHOU, CHINA TEL: +86 20 3222 2180 www.waterco.com Waterco Limited ABN 62 002 070 733 Waterco Limited ABN 62 002 070 733 (ZZM1836) 09/2024...
  • Page 2: Table Of Contents

    Pool Heat Pump Has Ice Formed On The Electrical Wiring Schematic Evaporator Coil • Waterco pool heat pumps must be installed by a suitably qualified person in accordance Electrical Wiring Schematic Pool Heat Pump Is Functioning, But Does Not with current Regulatory Standards, the applicable Wiring Rules (AS3000) and local Water Pump Control &...
  • Page 3: A Note To You

    During certain periods it may be necessary to operate your pool heat pump continuously during the day in cooler periods however, this should not be of concern as your Waterco pool heat pump can heat up your pool approximately 80% more Model Number ______________________________________________________ economically than the fossil fuel heating or heaters with electric elements.
  • Page 4: Installation Instructions

    05 I Pool Heat Pump Pool Heat Pump I 06 INSTALLATION INSTRUCTIONS Installation Clearances Air is pulled through the evaporator coil at the rear of the unit and discharged from Location the two front fan grills. Clearances must be allowed in front and around the unit for To gain maximum efficiency for your pool heat pump please follow all instructions unrestricted air discharge and service access.
  • Page 5: Installation

    A bypass kit consisting of 3 X two way valves must be installed for adjustment of water flow and ease of service. Waterco offer prefabricated water bypass kits to fit their heat pump domestic range. Ask your local Waterco sales office for details.
  • Page 6: Plumbing Diagram

    It may be necessary to install an earth leakage circuit breaker. water outlet Chlorinator cell valve (or other treatment Waterco recommend connecting the unit to an isolating switch to allow ease of service and maintenance. By -pass Filter valve water...
  • Page 7: How To Connect To The Terminal Board

    11 I Pool Heat Pump Pool Heat Pump I 12 How to connect to the terminal board Electrical Wiring Diagram Note: The electrical terminals may be located either underneath the top panel on References for protecting devices and cable specification smaller models or via a side panel which is model dependent.
  • Page 8 Breaker/fuse (Customer prepare) Power cord Earthing Power Supply 230V~/50Hz Water Pump Customer remote control switch Breaker/fuse Water Pump (Customer prepare) Power Supply 230V~/50Hz Earthing...
  • Page 9: Electrical Wiring Schematic

    15 I Pool Heat Pump Pool Heat Pump I 16 Electrical wiring schematic Water pump control and timer connection 1: Water pump timer Water Pump: 400V Voltage Breaker/fuse Power Supply (Customer prepare) 400V~/50Hz Power cord 2: Water pump wiring of Heat Pump Earthing Note: The installer should connect 1 parallel with 2 (as above picture).
  • Page 10: Performance Specifications

    17 I Pool Heat Pump Pool Heat Pump I 18 Performance Specifications Wi-Fi Operation NOTE: It is essential the heat pump is able to connect to the premise wifi signal. Premise owners are Nominal Output 11kW 14kW 19kW 27kW 32kW 41kW responsible for supplying a strong wifi signal to the area the heat pump will be installed to ensure the app functionality operates correctly.
  • Page 11: Wi-Fi Operation

    19 I Pool Heat Pump Pool Heat Pump I 20 Wi-Fi Operation Wi-Fi Operation APP Pairing Register through third-party application a. With Bluetooth 1. Please confirm that you’re connected to Wi-Fi and your Bluetooth is on. 2. Click “Add Device”, and then follow the instructions to pair device.
  • Page 12: Operation

    21 I Pool Heat Pump Pool Heat Pump I 22 Wi-Fi Operation Wi-Fi Operation a. With Wi-Fi Operation 1. Please make sure you are connected to Wi-Fi. 1. For heat pump with Heating function only: 2. Press “ ”for 3 seconds to unlock the screen. Press “...
  • Page 13: Share Devices To Your Family Members

    The heat pump can work between air -15°C~43°C, b. Temperature of heating 18°C~40°C Waterco ECO-VS pool heat pumps do not require the water by pass valves adjusted c. Temperature of cooling 12°C~30°C to cope with cooler water temperatures. In the event of low water temperatures, the Ideal operation range is between air 15°C ~ 25°C.
  • Page 14: Pool Heat Pump Running Time

    25 I Pool Heat Pump Pool Heat Pump I 26 Pool Heat Pump Running Time Operation Guide Most units should be sized to operate during the pool filtering cycle time of 8-10 daytime hours daily during warmer months and up to 8 hours daily during the Key Function daytime in winter months.
  • Page 15: Screen Display

    27 I Pool Heat Pump Pool Heat Pump I 28 Screen Display Operation Instruction Plugged without turning on Screen Lock 1. There is automatic screen lock function. No operation for more than 30 seconds, screen will automatically lock, and screen will dim while the lock button will light on, and other button light will be off.
  • Page 16 29 I Pool Heat Pump Pool Heat Pump I 30 Operation Instruction Operation Instruction Operating frequency Defrosting Compressor icon lights on during operation. Operation frequency speed will be 1. Automatic defrosting: When machine is auto defrosting, will flash, and return showed on screen as below: to previous working mode when it finishes.
  • Page 17: Maintenance Of Your Pool Heat Pump

    MAINTENANCE OF YOUR POOL HEAT PUMP Winterising Procedure Waterco pool heat pumps have been specifically engineered to give you years of satisfaction and enjoyment in the pool. If the pool heat pump is stored in a place where the temperature drops below the freezing point of 0˚C / 32°F;...
  • Page 18: General Safety Instructions

    Please ensure the unit and any related equipment is installed in accordance with the HOURS WITHOUT DRAINING IT. Make sure you leave the bypass valves as shown installation manual. If not, the Waterco warranty will not apply and the customer may in Figure 1.
  • Page 19: Fan Blades Turn, But Compressor Is Not Functioning

    2. Open the bypass valve. (refer to drawing on page 5) 3. Close the IN and OUT water valves on the unit. 4. Waterco recommend the use of a solar cover to retain heat in pool water. Pools 4. Restart the pool pump. The pool heat pump must remain OFF.
  • Page 20: Circuit Breaker Trips

    If you have purchased a remote control (or other equipment), ensure the equipment is correctly installed. If an operational issue originates from incorrect operation or installation of this equipment, Waterco’s warranty will not apply and you will have to pay the cost of the service call.
  • Page 21: Failure Solution And Code

    39 I Pool Heat Pump Pool Heat Pump I 40 Failure solution and code Parameter table Tap the mode key to enter. Failure Reason Solution Display Protection code description When powered on, the This is normal. Please wait until Startup code No water protection controller displays a code it disappears.
  • Page 22: Warranty

    E. Damage, issues caused by the use of an accessory, component or equipment not 7. Prior to contacting Waterco for assistance or service, in order to qualify for a warranty supplied by Waterco. claim, the original purchaser must have the model name and serial number along with a proof of the original purchase date.
  • Page 23 43 I Pool Heat Pump Pool Heat Pump I 44 Note: Note:...

Table of Contents