INTUITY Messaging Solutions Release 5 Migration Procedures
Connecting Release 3.1 or 3.2
12
To connect the external tape drive to DEFINITY AUDIX Release 3.1 or
3.2 for the backup:
1. Log in to the DEFINITY AUDIX machine using the craft login.
The system displays the DEFINITY AUDIX Command Prompt
screen.
2. Enter remove tape
The system displays the following message:
Press [enter] to execute or [cancel] to
abort:
3. Press F3 (Enter).
4. Remove the tape.
5. Enter reset system shutdown to shut down the DEFINITY
AUDIX.
The system displays the following message:
Press [enter] to execute or [cancel] to
abort:
6. Press F3 (Enter).
The system displays the following message:
Shutdown complete
!
WARNING:
Damage from electrostatic discharge is possible. For more
information, see Protecting against Damage from Electrostatic
Discharge (page xiii) in About This Book (page vii).
7. Remove the DEFINITY AUDIX from the host switch.
8. Remove the SCSI cable and clips that connect the DEFINITY
AUDIX tape drive to the Alarm Board (TN2169 or TN2170).
Remove the tape drive from the Alarm Board.
See Removing the Retaining Clips from the Tape Drive
(page 45). For more information about removing the tape drive,
see the DEFINITY AUDIX Maintenance manual.
585-313-118 Issue 4
June 2002