5
Setting up the screening station
of-interest. The Minimum value and Maximum value settings are used to specify this
percentage.
Depending on factors such as the distance to the camera and the type of camera lens,
you may have to adjust the Minimum value and Maximum value settings.
Note On the Live page you can change the size of the region-of-interest. If you do
that, you may have to adjust the Minimum value and Maximum value settings.
Custom status messages
• You can change the text that the screened person sees on the display. You may, for
example, want to add instructions for what the person shall do in case of a detected
elevated temperature.
Swap video streams (applicable to the screening window)
• Select the Swap video streams check box to change the display of the thermal and
visual video streams.
• Select the Mirror image horizontally check box to mirror (flip) the image.
• Select the Swap direction animations check box to change the direction of the arrows
that indicate that the person shall move closer or further back.
When all settings are completed, click Close in the bottom right corner of the page. This
closes the Settings page.
5.10.2.2 General tab
When the Log alarms to output folder check box on the Face detection tab is selected,
an image and a data file (*.csv) is automatically saved when an elevated skin tempera-
ture is detected. It is also possible to save images manually on the Live page.
Save dual snapshot separately
• When this check box is cleared, a combined thermal and visual image will be saved.
• When this check box is selected, a separate visual image will be saved in addition to
the combined thermal and visual image.
When the Open output folder after saving snapshot check box is selected, the folder with
the saved image will open when the saving is completed.
To change the file path to the folder where you want to store saved images, click Browse
and then select the folder.

5.11 Ensure correct setup

• Make sure the camera is mounted in a low position.
• Make sure the camera lens is angled a bit upwards, so that it aims at the head of a
person standing at the screening position.
• Make sure the backdrop is placed so that it fully covers the background that the cam-
era sees.
• Make sure the screening position is clearly marked, e.g. by a floor sticker.
• For accurate temperature measurements, it is very important that the thermal camera
focus is correct. To adjust the focus, do the following:
1. Place a person at the screening position. Make sure the face of the person covers
the face detection box.