Page 1
110448-P1 Rev E, 6/96 ® MKS Baratron Type 122A Absolute Pressure Gauge Hva bør jeg vurdere før han ble involvert i Leilighet Fremleie?
Page 2
All rights reserved. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage or retrieval system, except as may be expressly permitted in writing by MKS Instruments, Inc.
Table of Contents Table of Contents Safety Procedures and Precautions..................1 Chapter One: General Information..................3 Introduction ....................... 3 How This Manual is Organized.................. 4 Customer Support ...................... 4 Chapter Two: Installation ...................... 5 How To Unpack the Type 122 Unit................5 Unpacking Checklist ..................
Page 4
Table of Contents Appendix A: Product Specifications..................19 Appendix B: Product Code.....................21 Index ............................23...
Page 5
List of Figures List of Tables List of Figures Figure 1: Dimensions of a 122 Transducer................6 Figure 2: Electrical Connections .................... 7 Figure 3: Interface Cables for the 122 Transducer ..............9 Figure 4: Type 122 Transducer ....................11 Figure 5: Cross Sectional View of a 122 Transducer ..............
DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT Do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to an MKS Calibration and Service Center for service and repair to ensure that all safety features are maintained.
Page 8
Safety Procedures and Precautions OPERATE AT SAFE INLET PRESSURES This unit should never be operated at pressures higher than the rated maximum pressure (refer to the product specifications for the maximum allowable pressure). INSTALL A SUITABLE BURST DISC When operating from a pressurized gas source, a suitable burst disc should be installed in the vacuum system to prevent system explosion should the system pressure rise.
Introduction Chapter One: General Information Introduction ® The MKS Baratron Type 122A Absolute Pressure Transducer marks the beginning of a new era ® in low cost pressure measurement. Using a latest-generation single-sided dual-electrode Inconel sensor coupled with a new fixed-frequency bridge signal conditioner, the 122 provides operation...
Calibration and Service Center before shipping. The ERA Number expedites handling and ensures proper servicing of your instrument. Please refer to the inside of the back cover of this manual for a list of MKS Calibration and Service Centers. Warning All returns to MKS Instruments must be free of harmful, corrosive, radioactive, or toxic materials.
Chapter Two: Installation How To Unpack the Type 122 Unit MKS has carefully packed the Type 122 unit so that it will reach you in perfect operating order. Upon receiving the unit, however, you should check for defects, cracks, broken connectors, etc., to be certain that damage has not occurred during shipment.
Chapter Two: Installation Cables Certain interface cables can be supplied by MKS, or you may choose to make your own, provided the appropriate specifications contained herein are maintained. Refer to Figure 3, page 9, for the part numbers for the cables used with various MKS Readout/Controller Systems.
Page 15
Chapter Two: Installation Setup Digital Readouts CB473-1 PDR-C-1C/2C PDR-5B PDR-D-1 CB222 Analog Readout TYPE 122 TRANSDUCER CB112-2 Controllers CB254-2 Controllers Figure 3: Interface Cables for the 122 Transducer...
Page 16
Setup Chapter Two: Installation This page intentionally left blank.
Chapter Four: Operation How To Adjust the Zero Chapter Four: Operation How To Adjust the Zero The 122 transducer zero should be adjusted by first pumping to a pressure below the gauge resolution, and then setting the ZERO potentiometer for an output of zero volts (display reads “0000”).
How To Adjust the Zero Chapter Four: Operation Suggested Pressures for Zero Adjustment Model Number Full Scale Lowest Lowest Highest Base Warm-Up Range Suggested Suggested Pressure for Time Before (Torr) Pressure Proper Zero Adjusting Zero Pressure Reading (Torr) Control (Torr) Adjust (Torr) (Minutes) 122AA-00010-...
Instruments immediately. If it is necessary to return the unit to MKS, obtain an ERA number (Equipment Return Authorization Number) from a MKS Service Center before shipping. Please refer to the inside back cover of this manual for a list of MKS Calibration and Service Centers. Warning All returns to MKS Instruments must be free of harmful, corrosive, radioactive, or toxic materials.
Page 24
Sensor Chapter Five: Maintenance This page intentionally left blank.
Page 25
Appendix A: Product Specifications Appendix A: Product Specifications Accuracy (non-linearity, hysteresis, and non- ± 0.5% of Reading (optional ± 0.15%) repeatability) ± temperature coefficients CE Mark Compliance EMC Directive 89/336/EEC Fittings Standard ½” (12.7 mm) tubulation; ® ® Cajon 8-VCR only on 5K and higher ranges ®...
Page 26
Appendix A: Product Specifications This page intentionally left blank.
Page 27
Appendix B: Product Code Appendix B: Product Code Product Code The desired instrument options are identified in the product code when you order the unit. The product code is identified as follows: #### A-XXXXX Y Z where: #### XXXXX Type Number Sensor Type Full Scale Range Fittings...
Page 28
Appendix B: Product Code Full Scale Range - mmHg (XXXXX) The full scale range is indicated by a five digit code. Ordering Code 00010 00100 1000 01000 5000 05000 10000 10000 15000 15000 20000 20000 25000 25000 Fittings (Y) Four types of fittings are available, designated by a single letter code. Ordering Code ½”...
Page 29
Index Index fittings, 7 mounting instructions, 7 Cables, 8 Customer support, 4 Dimensions, 6 Fittings, 7 Installation checklist, 5 Maintenance, 17 Manual organization, 4 Messages, definitions of, 2 Operation zero adjust, 15 Returning the product, 4, 5 Safety procedures and precautions, 1 Setup cables, 8 electrical installation, 7...
Need help?
Do you have a question about the Baratron 122A Series and is the answer not in the manual?
Questions and answers