9 | Configuration and operation
ð The device begins the update.
- The update has been imported in full when the message „Actualización de Software realizada con éxito. " appe-
ars.
- If the update fails, the message "Actualización de Software incompleta!" appears.
3. When an error occurs, the update process must be repeated.
You can check to see if the update was successful in the menu:
Displaying the firmware version
F Open the Información / Versión SW menu.
ð The device will display the versions and checksums of the software that is currently loaded.
9.7

Access via Modbus

AVISO
In order to make use of the Modbus functionality, we recommend using the "SunSpec-Modbus-Interface" spe-
cification we have made available for the firmware version installed on your device.
Follow the description in the document "Modbus-Protokol.pdf" in order to use the two Excel files with a high
level of process reliability.
↻ Firmware version of device is identical to the specifications of the Sunspec® Modbus®.
1. Enable the entry Network – Modbus TCP - Operation mode / Network services – Modbus TCP
- Operation mode in the menu on the device or on the web interface.
2. If necessary, allow write access.
3. Set up the Port for access. [Default: 502]
ð Access via Modbus enabled.