Huawei EchoLife OT925-G User Manual page 75

Table of Contents

Advertisement

EchoLife OT925-G
User Guide
Procedure
Click Device Information > TDM Statistics to display the query page.
Click a desired sub-page to query the information.
----End
Parameter Description
Parameters of the TDM Logic Statistics page
Parameters of the ErrSecond Statistics page
Issue 02 (2007-08-30)
Parameter
8K frame statistics at GMAC
entrance
Lose frame statistics at GMAC
entrance
Duplex frame statistics at
downstream HTB entrance
Duplex frame statistics at
upstream HTB entrance
GEM frame length area error
statistics at GMAC entrance
Parameter
Num[L0]–Num[L3]
Error Second
Severe Error Second
Invalid Error Second
Huawei Technologies Proprietary
Parameter Description
Statistics of 8K frames at the GMAC entrance, that is,
statistics of total received TDM frames.
Statistics of dropped frames at the GMAC entrance,
that is, statistics of total dropped TDM frames.
Statistics of duplex frames at the downstream HTB
entrance.
Statistics of duplex frames at the upstream HTB
entrance.
Statistics of GEM frame length errors at the GMAC
entrance.
Parameter Description
Mapping four E1 ports of the OT925-G.
Statistics of error seconds. Statistics of the time when the
E1 port or link is faulty.
Statistics of severe error seconds. Statistics of the time
when the E1 port or link is severely faulty.
When the severe fault keeps there for consecutive 10s,
the E1 port or link is considered unavailable, and the
device starts counting invalid error seconds.
Statistics of invalid error seconds, that is, statistics of the
time when the E1 port or link is unavailable.
When there is no severe fault for consecutive 10s, the E1
port or link is considered available, and the device stops
counting invalid error seconds.
Tables
lxix

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V100r002

Table of Contents