Product Name and Model Number
User Manual
C2-260/inBio2-260 Access Control Panel
Date: June 2020
Doc Version: 1.0
English
Thank you for choosing our product. Please read the instructions carefully
before operation. Follow these instructions to ensure that the product is
functioning properly. The images shown in this manual are for illustrative
purposes only.
P a g e
| 1
For further details, please visit our Company's website
www.zkteco.com.
Copyright©2020 ZKTECO CO., LTD. All rights reserved.
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C2-260/inBio2-260 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZKTeco C2-260/inBio2-260

  • Page 1 Follow these instructions to ensure that the product is functioning properly. The images shown in this manual are for illustrative purposes only. For further details, please visit our Company’s website www.zkteco.com. P a g e Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 2 Copyright © 2020 ZKTECO CO., LTD. All rights reserved. Without the prior written consent of ZKTeco, no portion of this manual can be copied or forwarded in any way or form. All parts of this manual belong to ZKTeco and its subsidiaries (hereinafter the "Company" or "ZKTeco").
  • Page 3 C2-260/inBio2-260 Access Control Panel User Manual relating to the use of the information contained in or referenced by this manual, even if ZKTeco has been advised of the possibility of such damages. This manual and the information contained therein may include technical, other inaccuracies or typographical errors.
  • Page 4 User Manual About the Company ZKTeco is one of the world’s largest manufacturer of RFID and Biometric (Fingerprint, Facial, Finger-vein) readers. Product offerings include Access Control readers and panels, Near & Far-range Facial Recognition Cameras, Elevator/floor access controllers, Turnstiles, License Plate Recognition (LPR) gate controllers and Consumer products including battery-operated fingerprint and face-reader Door Locks.
  • Page 5 The general information which helps in performing the operations faster The information which is significant Care taken to avoid danger or mistakes The statement or event that warns of something or that serves as a cautionary example. P a g e Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 6: Table Of Contents

    DD A USER AND A CARD .......................... 41 CCESS ONTROL ETTINGS ..........................41 TIME MONITORING ............................... 45 EPORTS STATEMENT ON THE RIGHT TO PRIVACY ......................47 ECO-FRIENDLY OPERATION ........................48 P a g e Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 7: Safety Instructions

    Replacing components: If it is necessary to replace a component, only the authorized technician can replace the accessories specified by the manufacturer. Security inspection: After the equipment is repaired, the technician must conduct security inspection to ensure proper working of the equipment. P a g e Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 8: Installation Instructions

    To save access control event records, export the data periodically from control panels. Prepare countermeasures according to application scenarios for unexpected power failure, like selecting power supply with UPS. P a g e Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 9 It is recommended to use the power supply delivered with the system as the control panel power supply. In a place with substantial magnetic interference, galvanized steel pipes or shielded cables are recommended, and proper grounding is required. P a g e Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 10: System Introduction

    Control panel dimensions: 116.5mm*96.5mm*31.3mm Control Panel Indicators When the C2-260/inBio2-260 is powered on, normally the POWER indicator (red) is lit constantly, the RUN indicator (green) shall flash slowly (indicating the system is normal), and other indicators are all off. COMM indicator (yellow): It flashes when the system is communicating with other devices (e.g., PC). When the indicator is flashing continuously, it indicates data transmission.
  • Page 11 C2-260/inBio2-260 Access Control Panel User Manual Indicator Diagram: P a g e | 10 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 12: Installation And Connection

    2) Fix the device to the guide rail. The following describes the wall installation process.  1) Drill holes on the wall 2) Fix the device with four screws P a g e | 11 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 13: Installation Of Access Control Panel Wires

    The access control wires must be separated according to heavy and light current; the control panel wires, electronic lock wires, and exit button wires must run through their casing pipes, respectively. P a g e | 12 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 14: Control Panel System Installation

    PC, access control management personnel can remotely perform various management functions, like adding/deleting a user, viewing event records, opening/closing doors, and monitoring the status of each door in real-time. P a g e | 13 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 15: Control Panel Connection Terminals

    IP address will restore to the default (192.168.1.201). The terminals above are set through the relevant access control software. Please see the respective software manual for further details. P a g e | 14 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 16: Connection With Door Sensors , Exit Switches , Auxiliary Input Devices , And Rs485 Extension Communication

    P a g e | 15 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 17 Connections between Control Panel and Door Sensors, Exit Switches and Auxiliary Input Devices RS485 extension communication The Control panel supports extensive modules which like DM10 and AUX485, through RS485. A C2-260/inBio2-260 can connect eight DM10 at most or can connect two AUX485 at most. P a g e | 16...
  • Page 18: Connection With Rs485 Readers

    The connection between the Control Panel and RS485 Card Readers inBio2-260 TCP/IP 4# FR1200 3# FR1200 2# FR1200 1# FR1200 The connection between the Control Panel and Fingerprint Readers P a g e | 17 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 19: Relay Output Connection

    Relay Output Connection C2-260/inBio2-260 has three relays (two used as control locks by default, and the other one used as auxiliary outputs). The relays for auxiliary outputs may connect to monitors, alarms, doorbells, etc. Auxiliary outputs are set through the relevant access control software.
  • Page 20 C2-260/inBio2-260 Access Control Panel User Manual NC Lock Enlarged Lock diagram of lock ports Diode Power Input Diode Lock NO Lock Power Input Wiring diagram of lock connection P a g e | 19 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 21: Equipment Communication

    Metal wiring troughs and pipes must be connected P a g e | 20 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 22: Tcp/Ip Communication

    To enhance the stability of communication when the bus is longer than 300m, connect the provided 120-ohm terminal resistor between the 485A and 485B wires of the first and last control P a g e | 21 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 23: Dip Switch Settings

    For example, to set a device number as 15=1+2+4+8, which corresponds to the binary code 1111, move the numbers 1, 2, 3, and 4 to ON position . P a g e | 22 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 24: Zkbioaccess

    Activate the System Please refer to the corresponding license activation document. Modify Password You can modify the login password in the Personal Information section. P a g e | 23 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 25: Device

    When the communication is successful, you can view here the information of the connected devices, and perform remote monitoring, uploading and downloading, etc. P a g e | 24 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 26: Adding A Device

    The IP address can provide a cross-net segment, but it must be in the same subnet, and the Gateway and IP Address must be configured in the same network segment. P a g e | 25 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 27 Address in New Server Address is selected, then configure the IP address and port number. If Domain Address in New Server Address option is selected, then set the Domain address, port number, and DNS. The device will be added to the software automatically. P a g e | 26 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 28 Device > Synchronize All Data to Devices, otherwise, these original data may conflict with normal usage. P a g e | 27 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 29: I/O Board

    On the device module, click Device > I/O Board > New to add the I/O Board device to the software. Enter the name of the I/O Board. Select the Device by clicking the Device Name field. The device list appears, as shown below: P a g e | 28 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 30: Device Operation

    Users can edit the access controllers within the appropriate levels in the current system; users can only add or delete devices in Device Management if needed. P a g e | 29 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 31 Control Panel Type cannot be modified. If the type is wrong, users need to delete the device and add it again manually. Export  Device information can be exported in EXCEL, PDF, and CSV file formats. P a g e | 30 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 32 Synchronize All Data to Devices  To synchronize data of the system to the device, select the device and click Synchronize All Data to Devices and click OK to complete synchronization. P a g e | 31 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 33 After setting the time zone, the device will automatically synchronize the time according to the time zone and server time. Set as Registration device  P a g e | 32 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 34 It will define the condition of the master device as Entry or Exit. Get Device Option  It gets the common parameters of the device. For example, it gets the firmware version after the device is updated. P a g e | 33 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 35 (deletes 10 thousand transactions by default). View Rules of Devices  Shows the Access rules in the device. P a g e | 34 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 36 Then enter a new IP address, gateway, and subnet mask. Click OK to save and quit. This function is similar to [Modify IP Address Function] in Device. Modify Communication Password  P a g e | 35 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 37: Add A User And A Card

    Personnel ID. To edit the settings of the maximum number of characters of each personnel number and whether letters can also be used, click Personnel > Parameters. P a g e | 36 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 38 Register. Select a fingerprint, press the finger on the sensor continuously until the message “Fingerprint registered Successfully” is prompted. Click OK to complete the registration. P a g e | 37 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 39 [Allow the software to run or install even if the signature is ...], and remove the selection of [Check for server certificate revocation], then restart IE. If the browser version is below IE8, the fingerprint registration page will be different: P a g e | 38 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 40 The system supports access from the Live20R fingerprint device and the fake fingerprint prevention function. To set the Access Control parameters for the personnel, click Access Control. P a g e | 39 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 41 The Personnel Information List, by default, is displayed as a table. If Graphic Display is selected, photos and numbers will be shown. Place the cursor on a photo to view the details about the personnel. Notes: P a g e | 40 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 42: Access Control Settings

    For more details, please refer to “ZKBioAccess User Manual. ” Real-time monitoring Click Access Device > Real-Time Monitoring. It monitors the status and real-time events of doors configured to the access control panels in the system P a g e | 41 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 43 Door opening timeout, without relay Door lock status/Door Sensor Closed Without relay status, it indicates that the current firmware does not support the action on the device. P a g e | 42 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 44 Note: If Cancel the alarm fails, check if any devices are disconnected. If found disconnected, check the network. Remote Normally Open: It will set the device as normal open by remote. P a g e | 43 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 45 (including alarm events). Normal events will appear in green; alarm events will appear in red; other abnormal events will appear in orange. P a g e | 44 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 46: Reports

    Since the data quantity of access control event control is large, you can view the specific access control events through query conditions. By default, the system displays the last three months' transactions. Click Reports > All Transactions to view all the transactions. P a g e | 45 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 47 Clear All Data: This function is used to clear all the transactions. Click Clear All Data. In the appearing pop-up, click OK to remove all the transactions. Export: You can export all the transactions in Excel, PDF, and CSV format. P a g e | 46 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 48: Statement On The Right To Privacy

    Thank you for choosing this hybrid biometric recognition product, which was designed and manufactured by ZKTeco. As a world-renowned provider of core biometric recognition technologies, we are constantly developing and researching new products, and strive to follow the privacy laws of each country in which our products are sold.
  • Page 49: Eco-Friendly Operation

    The components which contain toxins or harmful elements are included due to the current economic or technical limitations which prevent their replacement with non-toxic materials or elements. P a g e | 48 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
  • Page 50 ZKTeco Industrial Park, No. 26, 188 Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 Fax : +86 755 - 89602394 www.zkteco.com Copyright © 2020 ZKTECO CO., LTD. All Rights Reserved. P a g e Copyright©2020 ZKTECO CO., LTD. All rights reserved.