Connection - Bartec BCS36 8ex Series Supplementary Description

Table of Contents

Advertisement

13.1.2

Connection

Diagram
Pos.
1
2
3
4
Universal supply module
Pos.
1
2
3
4
5
6
7
8
Page 62 of 78
BCS36x8
Series
ex
Type 17-A1S4-*HP* and B7-A2S4-****
Description
BCS 3678
hand-held scanner
ex
RS232 data cable from Ex-HMI device to the supply module Ex i BT (max. 15m)
Power supply (100 to 240 V
Note: NEC/CEC version only with 24V
Supply module Ex i BT for hand-held scanner
Ex-HMI device
Note: The Ex-HMI device can be replaced by any other Ex device with serial interface.
It is important that the Ex-relevant data must be compatible with the BARTEC
components. See BARTEC User Manual Chapter: "Ex-relevant values when connected
to power supply module or other systems".
Description
Cable gland
Cable gland
Terminals X1 to X2
Terminals X3 to X4
Shield clamp for ferrite core
Terminals X5 to X10
7-pole round plug
N/A in the Bluetooth version
Cover
Connection example
±10% / 50/60 Hz or 24 V
AC
.
DC
Function
Feed data cable to terminals
Feed power cord to terminals
Connect 100 to 240 V
Connect 24 V
The ferrite core is only needed when using the USB-
SPP interface.
Connect RS232 data line
Plug for wired hand-held scanner
Protect / seal terminal connection chamber
±10% 0.4A)
DC
power supply
AC
power supply
DC
Subject to technical changes.