Specifications

Specifications for the 71X Calibrators are based on a one-year calibration cycle and apply for
ambient temperatures from +18 °C to +28 °C unless stated otherwise. "Counts" are the
number of increments or decrements of the least significant digit. General specifications for
all models are in Table 2.
Maximum voltage applied between any
terminal and earth ground or between any
two terminals:
Storage temperature:
(718Ex) Pressure Sensor Media:
Operating temperature:
Operating altitude:
Relative humidity:
Safety
Electromagnetic Compatibility
International
Korea (KCC)
USA (FCC)
Power requirements: 712, 714, 715, 717
Power requirements: 718
Power requirements: 718Ex
Size: 712, 714, 715, 717
Size: 718, 718Ex, 719
Weight:
712
714
715
717 30G, 717 100G
718 30G and 718 100G and
718Ex 30G and 718Ex 100G
719
6
Table 2. General Specifications
30 V
712: -20 °C to 60 °C, 718Ex: -40 °C to 71 °C, 719: -30 °C to 60 °C
All other models: -40 °C to 60 °C
Non-corrosive gasses only
-10 °C to 55 °C
3000 meters maximum
95 % up to 30 °C
75 % up to 40 °C
45 % up to 50 °C
35 % up to 55 °C
IEC 61010-1: Pollution degree 2
IEC 61326-1: Basic Electromagnetic Environment; IEC 61326-2-1
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-
coupled radio frequency energy that is necessary for the internal function of the
equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic
and those directly connected to a low-voltage power supply network that
supplies buildings used for domestic purposes. There may be potential
difficulties in ensuring electromagnetic compatibility in other environments due to
conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and
may not provide adequate protection to radio reception in such environments.
Emissions that exceed the levels required by CISPR 11 can occur when the
equipment is connected to a test object.
The equipment may not meet the immunity requirements of this standard when
test leads and/or test probes are connected.
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103.
One 9 V battery (IEC 6LR61)
Two 9 V batteries (IEC 6LR61)
See "718Ex Approved Batteries".
34.9 mm H x 87 mm W x 187 mm L;
With holster and Flex-Stand:
52 mm H x 98 mm W x 201 mm L
60 mm H x 87 mm W x 210 mm L;
With holster: 66 mm H x 94 mm W x 216 mm L
337 g, With holster and Flex-Stand: 587 g
332 g, With holster and Flex-Stand: 584 g
349 g, With holster and Flex-Stand: 601 g
369 g, With holster and Flex-Stand: 624 g
737 g, With holster: 992G
912 g: With holster