10. Next step is to define the Alarm sequence. Go to
.
tions
In the configuration below, alarms sent to Personnel Day will be active for 240
seconds. If no one take care of the alarm, the alarm will be sent to group Person-
nel Night. If Personnel Night doesn't take care of the alarm within 240 seconds, the
alarm is lost forever. The same goes for Alarm sequence: Personnel Night but the
opposite way.
Picture 80. Define alarm sequence definition(s)
It is recommended to configure Duration (s) to a higher value to prevent alarms from
being lost.
11. To enable our sequences we need to configure Alarm distribution. Support for
Assistance alarms can also be enabled from Alarm distribution. Go to
.
Alarm distribution
The configuration below enables user alarms to be sent to Personnel Day or Person-
nel Night depending on system time. We have also enabled support for Assistance
alarms by configuring Order 3 to 6.
Picture 81. Define alarm distribution routing
Note that Alarm reset is configured to Yes. If someone accepts an Alarm or Assistance
alarm, it will disappear from other D-TREX 2G devices. If you are configuring a fire
alarm, you probably want to configure Alarm Reset to No for that specific distribution.
>
Routing
Alarm sequence defini-
Routing