Neat D-SERVER Technical Handbook page 55

Table of Contents

Advertisement

System parameter
debug-signals
debug-sip-task
debug-xml-tables
door-lock-pulse-time-person-
nel-sec
door-lock-pulse-time-users-
sec
door-opening-broadcast-send-
count
door-opening-forced-open-
interval-minutes
door-opening-forced-open-
time-minutes
door-opening-ignore-time-sec
door-opening-number-long-tx
door-opening-number-short-tx
door-opening-position-alarm-
from-datom-personnel
door-opening-position-alarm-
from-datom-user
door-opening-require-button-
press
door-opening-trigger-alarm-
from-datom-personnel
door-opening-trigger-alarm-
from-datom-user
feature-door-opening-enabled
feature-personnel-location-
info-enabled
feature-presence-indication-
enabled
feature-rfid-reception-enabled
feature-task-registration-
enabled
feature-user-position-logging-
enabled
group-info-send-count
ip-alive-time-check-sec
NE41 09010-02 v3.0
Description
Logging of signals received by the D-SERVER ap-
plication (reloading the D-SERVER settings and
stopping the D-SERVER application).
Logging of the SIP communication.
Introduced in Application v1.19.00
Logging of configuration tables.
Determines how long the door should be kept open
for personnel (in seconds).
Determines how long the door should be kept open
for users (in seconds).
How many transmissions a forced door opening
will send.
How long to wait before starting transmission of
the forced door opening again.
How long the door should be open during the
forced door opening.
After a door opening job has completed, this con-
trols how long to ignore a new door opening job
from the same device.
How many messages with long preamble to send.
How many messages with short preamble to send.
This parameters controls if the personnel has a
D-ATOM/SMILE device that sends a position alarm,
if a door opening job should be sent.
This parameters controls if the user has a D-ATOM /
SMILE device that sends a position alarm, if a door
opening job should be sent.
D-TREX 2G Return button is not required to open
doors if disabled.
This parameters controls if a trigger alarm (alarm
reason NONE) from a personnel should start a door
opening job.
This parameters controls if a trigger alarm (alarm
reason NONE) from a user should start a door
opening job.
Enable door opening in the system.
Controls if the "Where is" function in the D-TREX 2G
should be enabled.
Controls if presence should be activated in the
system.
Controls if RFID reception should be activated on
the D-TREX 2G.
Enable Task registration. Disabled by default.
Controls if user position should be logged and
displayed in the web interface.
Controls how many transmissions to send to a
D-TREX with group information.
Controls the interval that D-CALL/D-TECT IP should
send heartbeat messages.
Default value
1
0
0
3
30
30
2
5
5
0
3
1
1
1
0
0
0
0
0
0
0
0
5
240
D-SERVER Technical Handbook