2.1.1.3 Ethernet Interface Description
SICAM Q100 is equipped with an Ethernet interface. The data are exchanged via the RJ45 Ethernet plug con-
nector located on the top side of the device.
Ethernet
connector
RJ45
Figure 2-3
The Ethernet interface is characterized by the following parameters:
Transmission rate:
Protocol:
Connection:
Connecting cable:
SICAM Q100 features an internal Ethernet switch. It is therefore possible to connect a Y-cable (see device
manual, Accessories section) to the Ethernet interface in order to cascade devices with an Ethernet interface.
The internal Ethernet switch can be enabled or disabled in the parameterization.
SICAM Q100, 7KG95xx, System Manual
E50417-C1040-C522-A8, Edition 09.2020
RJ45 Ethernet Plug Connector
10/100 Mbit/s
IEEE802.3
100Base-T (RJ45), pinout according to DIN EN 50173, automatic patch/
crossover cable recognition
100  to 150  STP, CAT5 (shielded twisted-pair cable), max. 100 m if well
installed