Velocity: Fct. 3.2.12
This function provides an additional measurement parameter. This is particularly useful when the velocity
of hazardous materials is to be monitored where static build up is a danger. The mass flow meter will
calculate the velocity based on the tube diameter and the mass flow rate. In this menu the units for velocity
may be selected.
Key
From
Language: Fct. 3.2.13
The language of choice may be selected from this menu.
Key
From
Note: The language in the text will only change once you have exited the
programming mode and accepted the changes.
Concentration Measurement Fct. 3.3
Menu 3.3 is the Concentration menu.
If concentration has been ordered then please refer to the concentration manual, which will accompany the
meter.
Density Mode Fct. 3.4.1
This menu allows the user to select the type or mode of the density measurement.
Key
From
Display
Line 1
Fct. 3.2.12
Selects the velocity units. Choose from m/sec, ft/sec and off.
Accepts the selection.
Display
Line 1
Fct. 3.2.13
Selects further languages. Choose from Francais, Espanol,
Deutsch.
To select.
Display
Line 1
Fct. 3.4.1
Selects further options, e.g.
Fixed – This is used for products where the fixed density is used
for a volume calculation e.g. gas measurements.
Referred – Used for applications where the mass or volume of a
product is measured, referred to a base density.
Confirms the selection.
Installation and Operating Instructions OPTIMASS
Line 2
Velocity.
(off) - default
Line 2
Language
English
Line 2
Dens. mode
Actual
84