KROHNE OPTISWITCH 3300 C Operating Instructions Manual
Hide thumbs Also See for OPTISWITCH 3300 C:

Advertisement

Quick Links

Operating Instructions
OPTISWITCH 3300 C
- two-wire
Document
ID: 29963

Advertisement

Table of Contents
loading

Summary of Contents for KROHNE OPTISWITCH 3300 C

  • Page 1 Operating Instructions OPTISWITCH 3300 C - two-wire Document ID: 29963...
  • Page 2: Table Of Contents

    7 Maintenance and fault rectification Maintenance ........................22 Rectify faults ........................22 Exchanging the electronics module ................23 Instrument repair ......................24 Dismount Dismounting steps......................25 Disposal ......................... 25 Supplement Technical data ........................ 26 Dimensions ........................29 OPTISWITCH 3300 C • - two-wire...
  • Page 3 Supplementary documents appropriate to the ordered version come with the delivery. You can find them listed in chapter "Product descrip- tion". Instructions manuals for accessories and replacement parts Tip: To ensure reliable setup and operation of your OPTISWITCH 3300 C, we offer accessories and replacement parts. The corresponding documentations are: • Operating instructions manual "Oscillator" • Operating instructions manual "Lock fitting" Editing status:2014-05-26 OPTISWITCH 3300 C • - two-wire...
  • Page 4: About This Document

    This arrow indicates a single action. Sequence of actions Numbers set in front indicate successive steps in a procedure. Battery disposal This symbol indicates special information about the disposal of bat- teries and accumulators. OPTISWITCH 3300 C • - two-wire...
  • Page 5: For Your Safety

    During work on and with the device the required personal protective equipment must always be worn. Appropriate use The OPTISWITCH 3300 C is a sensor for point level detection. You can find detailed information about the area of application in chapter "Product description". Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions.
  • Page 6: Safety Label On The Instrument

    CE conformity This device fulfills the legal requirements of the applicable EC guide- lines. By attaching the CE mark, we provide confirmation of success- ful testing. SIL conformity OPTISWITCH 3300 C meets the requirements to the functional safety according to IEC 61508. Further information is available in the Safety Manual "OPTISWITCH 3XXX". Safety instructions for Ex areas Please note the Ex-specific safety information for installation and op- eration in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.
  • Page 7: Product Description

    Housing cover Housing with electronics Process fitting Principle of operation OPTISWITCH 3300 C is a point level sensor with tuning fork for point Application area level detection. It is designed for industrial use in all areas of process technology and is preferably used for bulk solids.
  • Page 8: Operation

    3 Product description Solid detection in water If OPTISWITCH 3300 C was ordered for solids detection in water, the tuning fork is set to the density of water. In air or when immersed in water (density: 1 g/cm³/0.036 lbs/in), OPTISWITCH 3300 C signals "uncovered". Only when the vibrating element is also covered with solids (e.g. sand, sludge, gravel etc.) will the sensor signal "covered". Function monitoring The electronics module of OPTISWITCH 3300 C monitors continu- ously the following criteria: •...
  • Page 9 Not exposed to corrosive media • Protected against solar radiation • Avoiding mechanical shock and vibration • Storage and transport Storage and transport temperature see chapter "Supplement - temperature Technical data - Ambient conditions" • Relative humidity 20 … 85 % OPTISWITCH 3300 C • - two-wire...
  • Page 10: Mounting

    You can find the specifications in chapter "Technical data" and on the nameplate. In general, OPTISWITCH 3300 C can be installed in any position. The Switching point instrument only has to be mounted in such a way that the vibrating element is at the height of the desired switching point.
  • Page 11: Mounting Instructions

    For this reason, do not use an overly long extension tube for OPTISWITCH 3300 C, but check if you can mount a short level switch on the side of the vessel in horizontal position.
  • Page 12 The tuning fork must be mounted in a way that takes the arrangement of the filling and emptying apertures into account. To compensate measurement errors caused by the material cone in cylindrical vessels, the sensor must be mounted at a distance of d/6 from the vessel wall. Fig. 4: Filling and emptying centred OPTISWITCH 3300 C • - two-wire...
  • Page 13 Fig. 5: Filling in the centre, emptying laterally OPTISWITCH 3300 C Discharge opening Filling opening Product flow To make sure the tuning fork of OPTISWITCH 3300 C generates as little resistance as possible to product flow, mount the sensor so that the surfaces are parallel to the product movement. OPTISWITCH 3300 C • - two-wire...
  • Page 14 In applications such as grit chambers or settling basins for coarse falling rocks sediments, the vibrating element must be protected against damage with a suitable baffle. This baffle must be manufactured by you. > 125 mm (> 5") Fig. 7: Baffle for protection against mechanical damage OPTISWITCH 3300 C • - two-wire...
  • Page 15: Connecting To Power Supply

    Proceed as follows: 1. Unscrew the housing cover 2. Loosen compression nut of the cable entry gland 3. Remove approx. 10 cm (4 in) of the cable mantle, strip approx. 1 cm (0.4 in) of insulation from the ends of the individual wires 4. Insert the cable into the sensor through the cable entry 5. Lift the opening levers of the terminals with a screwdriver (see following illustration) OPTISWITCH 3300 C • - two-wire...
  • Page 16: Wiring Plan, Single Chamber Housing

    The following illustrations apply to the non-Ex as well as to the Ex-d version. Housing overview Fig. 9: Material versions, single chamber housing Plastic (not with EEx d) Aluminium Stainless steel (not with EEx d) Filter element for pressure compensation (not with EEx d) OPTISWITCH 3300 C • - two-wire...
  • Page 17 For further information see the "Technical data" in the "Supplement". The wiring example is applicable for all suitable signal conditioning instruments. If the mode switch of OPTISWITCH 3300 C is correctly set to "max.", the control lamp on OPTISWITCH 3300 C lights. • red - with submerged vibrating element • green - with uncovered vibrating element Take note of the operating instructions manual of the signal condition- ing instrument.
  • Page 18: Setup

    • Signal lamp (5) Note: As a rule, always set the mode with mode switch (2) before starting the setup of OPTISWITCH 3300 C . If the instrument is used in con- junction with a signal conditioning instrument, always set the mode switch (2) on OPTISWITCH 3300 C to max. mode. The mode is selected on the signal conditioning instrument with the mode switch.
  • Page 19: Function Chart

    6 Setup With the potentiometer you can adapt the switching point to the solid. Switching point adapta- tion (1) It is already preset and must only be modified in special cases. By default, the potentiometer of OPTISWITCH 3300 C is set to the right stop (> 0.02 g/cm³ or 0.0008 lbs/in³). In case of very light-weight solids, turn the potentiometer to the left stop (> 0.008 g/cm³ or 0.0003 lbs/in³). OPTISWITCH 3300 C will thus be more sensitive and can detect light-weight solids more reliably.
  • Page 20 The following chart provides an overview of the switching conditions depending on the adjusted mode of the signal conditioning instru- ment and the level. Note: Keep in mind that the mode switch of OPTISWITCH 3300 C must be always set to "max.". Mode on the signal Level...
  • Page 21 Mode on the signal Level Signal current - Signal lamp - sen- Signal lamp - sig- conditioning in- Sensor nal conditioning strument instrument Mode B approx. 8 mA Dry run protection Green Fault message < 2.3 mA (mode A/B) flashes red OPTISWITCH 3300 C • - two-wire...
  • Page 22: Maintenance And Fault Rectification

    Exchanging the electronics module tronics module instrument defective Exchange the instrument or send it in for repair Reaction after fault recti- Depending on the reason for the fault and the measures taken, the fication steps described in chapter "Set up" may have to be carried out again. OPTISWITCH 3300 C • - two-wire...
  • Page 23: Exchanging The Electronics Module

    9. Insert the electronics module carefully. Make sure that the plug is in the correct position. 10. Screw in and tighten the two holding screws with a screwdriver (Torx size T10 or Phillips 4) 11. Insert the wire ends into the open terminals according to the wir- ing plan OPTISWITCH 3300 C • - two-wire...
  • Page 24: Instrument Repair

    By doing this you help us carry out the repair quickly and without hav- ing to call back for needed information. • Print and fill out one form per instrument • Clean the instrument and pack it damage-proof • Attach the completed form and possibly also a safety data sheet to the instrument OPTISWITCH 3300 C • - two-wire...
  • Page 25: Dismount

    WEEE directive. Correct disposal avoids negative effects on humans and the environ- ment and ensures recycling of useful raw materials. Materials: see chapter "Technical data" If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. OPTISWITCH 3300 C • - two-wire...
  • Page 26: Supplement

    Ʋ American pipe thread, conical 1½ NPT (ASME B1.20.1) Weight approx. Ʋ Instrument weight (depending on 0.8 … 4 kg (0.18 … 8.82 lbs) process fitting) Ʋ Extension tube 2000 g/m (21.5 oz/ft) Sensor length (L) 0.3 … 6 m (0.984 … 19.69 ft) Max. lateral load 290 Nm, max. 600 N (214 lbf ft, max. 135 lbf) Fig. 36: Max. lateral load alongside fork side (narrow fork side) OPTISWITCH 3300 C • - two-wire...
  • Page 27 200°C 250°C (-58°F) (122°F) (212°F) (302°F) (392°F) (482°F) -40°C (-40°F) Fig. 37: Ambient temperature - Process temperature Process temperature Ambient temperature Temperature range with temperature adapter Product density Ʋ Standard > 0.02 g/cm³ (0.0007 lbs/in³) Ʋ adjustable > 0.008 g/cm³ (0.0003 lbs/in³) OPTISWITCH 3300 C • - two-wire...
  • Page 28 Overvoltage category Protection class Approvals Depending on the version, instruments with approvals can have different technical data. For these instruments, please note the corresponding approval documents. They are included in the scope of delivery. Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF. OPTISWITCH 3300 C • - two-wire...
  • Page 29: Dimensions

    ~ 69mm ") ") ø 77mm ") ø 84mm ø 77mm ") ") ") M20x1,5/ M20x1,5/ M20x1,5/ M20x1,5 ½ NPT ½ NPT ½ NPT Fig. 38: Housing versions Plastic housing Stainless steel housing Aluminium housing OPTISWITCH 3300 C • - two-wire...
  • Page 30 9 Supplement G1½ ø 43 mm (1.69") Fig. 39: OPTISWITCH 3300 C, threaded version G1½ A (DIN ISO 228/1) Sensor length, see chapter "Technical data" OPTISWITCH 3300 C • - two-wire...
  • Page 31 9 Supplement ø 34 mm (1.34") Fig. 40: Temperature adapter OPTISWITCH 3300 C • - two-wire...
  • Page 32 Subject to change without notice 29963-EN-140630...

Table of Contents