INSTRUCTIONS FOR INSTALLATION
OF THE CARBON FILTER
1. Remove the worn out filter from the air
duct neck.
2. Remove the protective package of a
new filter.
3. Put the filter to the air duct neck so
that the air passage direction corre-
sponds
to
the
passage
through the filter in accordance with
the arrow on the filter. The inlet air
should pass to the white duct filtration
layer first.
4. Check proper sealing of the filter.
5. Fix the filter.
MAINTENANCE INSTRUCTIONS
E13
DRAINAGE OF CONDENSATE FROM
AIR ACCUMULATOR
Drain condensate by pulling the ring to
deflect the bleeding valve.
The valve is installed on the air accumu-
lator bottom.
direction
G731
CHECK OF TIGHTNESS OF AIR
SYSTEMS
 Fill the air accumulator up to the
 When the engine is stopped, pressure
171
maximum pressure (730  20 kPa).
may not drop by more than 10 kPa.
Carry out checks every day be-
fore you drive out with a trailer or
semi-trailer!
A warning light on the dashboard
lights on in case of a drop of
pressure in the brake system un-
der 450
30 kPa!