Fault
code No.
Designation
119
LOLO ECU Supply
Voltage
120
HI ECU Supply Voltage
121
HIHI ECU Supply
Voltage
122
HI T-ECU
134
15V POS ECU DEFECT
136
15V NEG ECU DEFECT
139
L1 TE BUFFER TEST
140
TE BUF. ECU DEFECT
142
BANK1 ECU DEFECT
144
BANK2 ECU DEFECT
15V_GOOD ECU
145
DEFECT
146
L1 AD-TEST1 SUPPLY
AD-TEST1 ECU
147
DEFECT
148
L1 AD-TEST2 SUPPLY
M015715/00E 06-08
Meaning
Alarm configuration limit value
2; Main warning: Supply
voltage too low.
Alarm configuration limit value
1; Preliminary warning: Supply
voltage too high.
Alarm configuration limit value
2; Main warning: Supply
voltage too high.
Alarm configuration limit
value 1; Preliminary warning:
Temperature in ECU too high.
Internal voltage (-15 VDC)
faulty; automatic engine
shutdown.
Internal voltage (-15 VDC)
missing; automatic engine
shutdown.
Supply voltage of temperature
sensors faulty.
Supply voltage of temperature
sensors faulty.
Power output stage for control
of the solenoid valves on bank
1 is faulty; Engine does not
start.
Power output stage for control
of the solenoid valves on bank
2 is faulty; Engine does not
start.
Power supply faulty; automatic
engine shutdown.
Supply voltage A/D converter
too low.
Electronic fault; automatic
engine shutdown.
Supply voltage A/D converter
too low.
Task
1. Check ECU
supply voltage.
2. Contact
Service.
1. Check ECU
supply voltage.
2. Contact
Service.
1. Check ECU
supply voltage.
2. Contact
Service.
1. Reduce power.
2. Improve
engine room
ventilation.
Replace ECU.
Contact Service.
1. Check sensors.
2. Replace ECU.
3. Contact
Service.
1. Check sensors.
2. Replace ECU.
3. Contact
Service.
Replace ECU.
Replace ECU.
Replace ECU.
Replace ECU.
Replace ECU.
Replace ECU.
77
Related
parameter No.
2.0140.922
2.0140.931
2.0140.932
2.0132.921
© MTU