Emissions (Epa) - MTU 20 V 4000 G23 Technical Publication

Hide thumbs Also See for 20 V 4000 G23:
Table of Contents

Advertisement

Product Summary
2.6.4
20V 4000 Gx3 engine data: Continuous operation, variable
3B, optimized exhaust emissions (EPA)
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power settings).
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
Application group
Intake air temperature
Charge-air coolant temperature
Raw-water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Number of cylinders
Rated engine speed
Continuous power ISO 3046 (10% overload capability)
(design power DIN 6280, ISO 8528)
GENERAL CONDITIONS (for maximum power)
Number of cylinders
Intake air depression (new filter)
Intake air depression, max.
Exhaust pressure
Exhaust pressure, max.
M015715/00E 06-08
4000 G43
°C
°C
°C
mbar
m
rpm
A
A
kW
A
mbar
L
mbar
A
mbar
L
mbar
20V
20V
4000 G83
3B
3B
25
25
45
45
-
-
1000
1000
100
100
20
20
1800
1800
2490
2740
20
20
15
15
50
50
30
30
85
85
39
20V
4000
G83L
3B
25
45
-
1000
100
20
1800
3010
20
15
50
30
85
© MTU

Hide quick links:

Advertisement

Table of Contents
loading