Torque Instructions - Graco Husky 1050 Series Operation

Air-operated diaphragm pump
Hide thumbs Also See for Husky 1050 Series:
Table of Contents

Advertisement

Maintenance

Torque Instructions

NOTE: Fluid cover and manifold fasteners
have a thread-locking adhesive patch applied
to the threads. If this patch is excessively worn,
the fasteners may loosen during operation.
Replace screws with new ones or apply
medium-strength (blue) Loctite or equivalent to
the threads.
If fluid cover or manifold fasteners have been
loosened, it is important to torque them using
the following procedure to improve sealing.
NOTE: Always completely torque fluid covers
before torquing manifolds.
Start all fluid cover screws a few turns. Then
turn down each screw just until head contacts
cover. Then turn each screw by 1/2 turn or less
working in a crisscross pattern until each
screw is torqued to 100 in-lb (11.3 N•m).
Repeat for manifolds. See F
Retorque the air valve fasteners (V) in a criss-
cross pattern to specified torque.
Plastic center sections: 55 in-lb (6.2 N•m)
Metal center sections: 80 in-lb (9.0 N•m)
16
. 7.
IG
1
4
3
2
7
5
8
6
F
. 7. Torque sequence
IG
2
3
4
1
ti13845a
6
8
5
7
V
ti13846a
312877A