Torque Instructions - Graco ChemSafe 1590 Instructions-Parts List Manual

Air-operated diaphragm pump
Hide thumbs Also See for ChemSafe 1590:
Table of Contents

Advertisement

Torque Instructions

Torque Instructions
Torque
Torque
Instructions
Instructions
If fluid cover or manifold bolts have been loosened,
it is important to torque them using the following
procedure to improve sealing.
Do not
not over
over- - - torque.
torque. Tightening the bolts too tight
Do
Do
not
over
torque.
will damage the pump.
NOTE: Always completely torque fluid covers before
NOTE:
NOTE:
torquing fluid manifolds.
1. Remove the protective bolt covers (37) with
a screwdriver. Carefully work the screwdriver
under the lip of each cap and gently pry it off.
2. Start all fluid cover screws a few turns. Then, turn
down each screw just until head contacts cover.
Fluid
Fluid Cover
Fluid
Cover Screws
Cover
Screws
Screws
24
Tel: 866-777-6060
Fax: 866-777-6383
NOTICE
NOTICE
NOTICE
Springer Pumps, LLC
3. Turn each screw by 1/2 turn or less working in a
crisscross pattern to specified torque.
4. Repeat for fluid manifolds.
Assembly
Torque
Fluid Covers
60 in-lb (6.8
N∙m)
Fluid
55 in-lb (6.2
Manifolds
N∙m)
Fluid
Fluid Manifold
Fluid
Manifold
Manifold Screws
Screws
Screws
Website: www.springerpumps.com
Re-Torque
55 in-lb (6.2
N∙m)
45 in-lb (5.1
N∙m)
334796G
Int'l: +001 267 404 2910