Page 1
Operation ® Husky 1050 Air-Operated 312877ZAD Diaphragm Pump 1-inch pump with modular air valve for fluid transfer applications. For professional use only. See page 4 for model information, including approvals. 125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure 125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure 1050P Polypropylene...
To find part numbers for new pumps or kits, use the Online Husky Selector Tool. To find part numbers for replacement parts: Use the configuration number from the ID plate on the pump. If you only have the Graco 6-digit part num- ber, use the selector tool to find the corresponding configuration number.
Pump Matrix Pump Matrix PART NO. CONFIGURATION NO. SERIAL NO. DATE CODE SERIES MAX WPR PSI-bar MADE IN Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump. Sample Configuration Number: 1050A-PA01AA1SSBNBNPT 1050 A01A...
ATEX Certifications ATEX Certifications All 1050A (Aluminum) and ‡ 1050S (Stainless Steel) and 1050H 1050A (Aluminum) and 1050C (Conductive 1050C (Conductive (Hastelloy) pumps with aluminum or Polypropylene) pumps with DataTrak or Pulse Count Polypropylene) pumps are conductive polypropylene centers are 1050S (Stainless Steel) and 1050H...
Page 6
Warnings WARNING SPECIAL CONDITIONS FOR SAFE USE Equipment must comply with the following conditions to avoid a hazardous condition which can cause fire or explosion. • All label and marking material must be cleaned with a damp cloth (or equivalent). •...
Page 7
Warnings WARNING PLASTIC PARTS CLEANING SOLVENT HAZARD Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. See Technical Specifications in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s warnings.
Installation Installation Graco recommends taking all of the above factors into account in system design. To maintain pump efficiency, The Typical Installation shown in F . 4 is only a guide supply only enough power to the pump to achieve the for selecting and installing system components.
1. For wall mounting, order Graco Kit 24C637. 2. Be sure the mounting surface can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.
(113). 3. Connect remaining ends of tubes to external air ™ Trapped air can cause the pump to cycle signal, such as Graco’s CycleFlo (PN 195264) or unexpectedly, which could result in serious injury from CycleFlo II (PN 195265) controllers.
Installation Air Exhaust Ventilation 2. Install a grounded air exhaust hose (U) and connect the muffler (T) to the other end of the hose. The minimum size for the air exhaust hose is 3/4 in. (19 mm) ID. If a hose longer than 15 ft (4.57 m) is required, use a larger diameter hose.
Installation Fluid Supply Line Fluid Outlet Line See F . 4, page 13. See F . 4, page13. 1. Use grounded, flexible fluid supply lines (G). See 1. Use grounded, flexible fluid hoses (L). See Grounding, page 9. Grounding, page 9. 2.
Page 13
Installation ti14164b . 4. Typical floor-mount installation (polypropylene, 1050P, pump shown) Key for F . 4: Fluid outlet (Aluminum, not pictured, four ports; Plastic, F . 4, center or end flanges available; A Air supply line Hastelloy and stainless steel, not pictured, one port) Bleed-type master air valve (required for pump) Ground wire (required for aluminum, conductive Air filter/regulator assembly...
Installation Fluid Inlet and Outlet Ports Graco standard pipe flange kits are available in polypropylene (239005), stainless steel (239008), and PVDF (239009). These kits include: NOTE: Remove and reverse the manifold(s) to change the orientation of inlet or outlet port(s). Follow Torque •...
Installation Fluid Pressure Relief Valve Some systems may require installation of a pressure Overpressurization also can occur if the Husky pump is relief valve at the pump outlet to prevent used to feed fluid to a piston pump, and the intake valve overpressurization and rupture of the pump or hose.
NOTICE thoroughly with a compatible solvent. See Flushing and When replacing Husky 1040s: The Husky 1050 Storage, page 17. operates more efficiently than did the 1040. Reduce air inlet pressure by approximately 20 percent to maintain Tighten Fasteners Before Setup an equivalent fluid output.
Maintenance 10. If you are flushing, run the pump long enough to Flushing and Storage thoroughly clean the pump and hoses. 11. Close the dispensing valve, if used. 12. Close the bleed-type master air valve. 13. Pumps with runaway protection: Disable the •...
Maintenance Torque Instructions NOTE: Fluid cover and manifold fasteners have a thread-locking adhesive patch applied to the threads. If this patch is excessively worn, the fasteners may loosen during operation. Replace screws with new ones or apply medium-strength (blue) Loctite or equivalent to the threads.
Dimensions and Mounting Dimensions and Mounting Aluminum (1050A) ti12212b ti12211b 5.0 in. (127 mm) 5.5 in. (140 mm) ti12213b ti14540b 10.2 in. (258 mm) 12.7 in. (323 mm) 1/2 npt(f) air inlet 14.4 in. (366 mm) 1 in. npt(f) or 1 in. bspt fluid inlet 15.9 in.
Dimensions and Mounting Polypropylene (1050P), Conductive Polypropylene (1050C) and PVDF (1050F) ti13845b ti13847b ti13846b 1/2 npt(f) air inlet 13.2 in. (335 mm) 1 in. ANSI/DIN flange 15.7 in. (399 mm) 1 in. ANSI/DIN flange 17.8 in. (452 mm) 3/4 npt(f) air exhaust port 12.0 in.
Dimensions and Mounting Hastelloy (1050H) and Stainless Steel (1050S) ti14343b ti14344b ti14345b ti14542b 1 in. npt(f) or 1 in. bspt fluid inlet ports (4) 11.8 in. (300 mm) 1 in. npt(f) or 1 in. bspt fluid outlet ports 12.9 in. (328 mm) 13.7 in.
Dimensions and Mounting Stainless steel (1050S) with center flange manifold ti29941a ti29942a 11.8 in. (300 mm) 14.9 in. (378 mm) 17.1/18.7 in. (434/475 mm) 11.5 in. (292 mm) 3.1 in. (79 mm) 7.35 in. (187 mm) 13.9 in. (353 mm) 15.0 in.
Dimensions and Mounting Stainless steel (1050S) with center tri-clamp manifold 11.8 in. (300 mm) 14.9 in. (378 mm) 15.9 in. (403 mm) 11.5 in. (292 mm) 3.1 in. (79 mm) 7.35 in. (187 mm) 13.9 in. (353 mm) 15.0 in. (381 mm) 3.8 in.
Technical Specifications Technical Specifications Maximum fluid working pressure ......125 psi (0.86 MPa, 8.6 bar) Air pressure operating range .
Page 26
Technical Specifications Non-wetted external parts Aluminum (1050A) aluminum, coated carbon steel Hastelloy (1050H) hastelloy, stainless steel, polypropylene or aluminum (if used in center section) Plastic (1050P, 1050C, and 1050F) stainless steel, polypropylene Stainless Steel (1050S) stainless steel, polypropylene or aluminum (if used in center section) Reference Information Maximum Storage Time (varies with conditions)
Page 27
Technical Specifications California Proposition 65 CALIFORNIA RESIDENTS WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov. 312877ZAD...
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of 12 months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
Need help?
Do you have a question about the Husky 1050 and is the answer not in the manual?