Graco Husky 1050 Operation

Graco Husky 1050 Operation

Air-operated diaphragm pump
Hide thumbs Also See for Husky 1050:

Advertisement

Quick Links

Operation
®
Husky
Diaphragm Pump
1-inch pump with modular air valve for fluid transfer applications. For professional use
only.
See page 4 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure
125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
1050A
Aluminum
ti13946a
1050 Air-Operated
1050S
Stainless Steel
1050H
Hastelloy
1050P
Polypropylene
1050C
Conductive
Polypropylene
1050F
PVDF
Center
Flange
End
Flange
ti14342a
312877ZAD
EN
ti13843a
ti13844a

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Husky 1050 and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco Husky 1050

  • Page 1 Operation ® Husky 1050 Air-Operated 312877ZAD Diaphragm Pump 1-inch pump with modular air valve for fluid transfer applications. For professional use only. See page 4 for model information, including approvals. 125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure 125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure 1050P Polypropylene...
  • Page 2: Table Of Contents

    Fluid Pressure Relief Valve ....15 Graco Information ......28 Operation .
  • Page 3: To Find Your Nearest Distributor

    To find part numbers for new pumps or kits, use the Online Husky Selector Tool. To find part numbers for replacement parts: Use the configuration number from the ID plate on the pump. If you only have the Graco 6-digit part num- ber, use the selector tool to find the corresponding configuration number.
  • Page 4: Configuration Number Matrix

    Pump Matrix Pump Matrix PART NO. CONFIGURATION NO. SERIAL NO. DATE CODE SERIES MAX WPR PSI-bar MADE IN Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump. Sample Configuration Number: 1050A-PA01AA1SSBNBNPT 1050 A01A...
  • Page 5: Warnings

    ATEX Certifications ATEX Certifications  All 1050A (Aluminum) and ‡ 1050S (Stainless Steel) and 1050H  1050A (Aluminum) and 1050C (Conductive 1050C (Conductive (Hastelloy) pumps with aluminum or Polypropylene) pumps with DataTrak or Pulse Count Polypropylene) pumps are conductive polypropylene centers are 1050S (Stainless Steel) and 1050H...
  • Page 6 Warnings WARNING SPECIAL CONDITIONS FOR SAFE USE Equipment must comply with the following conditions to avoid a hazardous condition which can cause fire or explosion. • All label and marking material must be cleaned with a damp cloth (or equivalent). •...
  • Page 7 Warnings WARNING PLASTIC PARTS CLEANING SOLVENT HAZARD Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. See Technical Specifications in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s warnings.
  • Page 8: Installation

    Installation Installation Graco recommends taking all of the above factors into account in system design. To maintain pump efficiency, The Typical Installation shown in F . 4 is only a guide supply only enough power to the pump to achieve the for selecting and installing system components.
  • Page 9: Mounting

    1. For wall mounting, order Graco Kit 24C637. 2. Be sure the mounting surface can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.
  • Page 10: Air Line

    (113). 3. Connect remaining ends of tubes to external air ™ Trapped air can cause the pump to cycle signal, such as Graco’s CycleFlo (PN 195264) or unexpectedly, which could result in serious injury from CycleFlo II (PN 195265) controllers.
  • Page 11: Air Exhaust Ventilation

    Installation Air Exhaust Ventilation 2. Install a grounded air exhaust hose (U) and connect the muffler (T) to the other end of the hose. The minimum size for the air exhaust hose is 3/4 in. (19 mm) ID. If a hose longer than 15 ft (4.57 m) is required, use a larger diameter hose.
  • Page 12: Fluid Supply Line

    Installation Fluid Supply Line Fluid Outlet Line See F . 4, page 13. See F . 4, page13. 1. Use grounded, flexible fluid supply lines (G). See 1. Use grounded, flexible fluid hoses (L). See Grounding, page 9. Grounding, page 9. 2.
  • Page 13 Installation ti14164b . 4. Typical floor-mount installation (polypropylene, 1050P, pump shown) Key for F . 4: Fluid outlet (Aluminum, not pictured, four ports; Plastic, F . 4, center or end flanges available; A Air supply line Hastelloy and stainless steel, not pictured, one port) Bleed-type master air valve (required for pump) Ground wire (required for aluminum, conductive Air filter/regulator assembly...
  • Page 14: Fluid Inlet And Outlet Ports

    Installation Fluid Inlet and Outlet Ports Graco standard pipe flange kits are available in polypropylene (239005), stainless steel (239008), and PVDF (239009). These kits include: NOTE: Remove and reverse the manifold(s) to change the orientation of inlet or outlet port(s). Follow Torque •...
  • Page 15: Fluid Pressure Relief Valve

    Installation Fluid Pressure Relief Valve Some systems may require installation of a pressure Overpressurization also can occur if the Husky pump is relief valve at the pump outlet to prevent used to feed fluid to a piston pump, and the intake valve overpressurization and rupture of the pump or hose.
  • Page 16: Operation

    NOTICE thoroughly with a compatible solvent. See Flushing and When replacing Husky 1040s: The Husky 1050 Storage, page 17. operates more efficiently than did the 1040. Reduce air inlet pressure by approximately 20 percent to maintain Tighten Fasteners Before Setup an equivalent fluid output.
  • Page 17: Datatrak Operation

    Maintenance 10. If you are flushing, run the pump long enough to Flushing and Storage thoroughly clean the pump and hoses. 11. Close the dispensing valve, if used. 12. Close the bleed-type master air valve. 13. Pumps with runaway protection: Disable the •...
  • Page 18: Torque Instructions

    Maintenance Torque Instructions NOTE: Fluid cover and manifold fasteners have a thread-locking adhesive patch applied to the threads. If this patch is excessively worn, the fasteners may loosen during operation. Replace screws with new ones or apply medium-strength (blue) Loctite or equivalent to the threads.
  • Page 19: Dimensions And Mounting

    Dimensions and Mounting Dimensions and Mounting Aluminum (1050A) ti12212b ti12211b 5.0 in. (127 mm) 5.5 in. (140 mm) ti12213b ti14540b 10.2 in. (258 mm) 12.7 in. (323 mm) 1/2 npt(f) air inlet 14.4 in. (366 mm) 1 in. npt(f) or 1 in. bspt fluid inlet 15.9 in.
  • Page 20: Polypropylene (1050P), Conductive Polypropylene (1050C) And Pvdf (1050F)

    Dimensions and Mounting Polypropylene (1050P), Conductive Polypropylene (1050C) and PVDF (1050F) ti13845b ti13847b ti13846b 1/2 npt(f) air inlet 13.2 in. (335 mm) 1 in. ANSI/DIN flange 15.7 in. (399 mm) 1 in. ANSI/DIN flange 17.8 in. (452 mm) 3/4 npt(f) air exhaust port 12.0 in.
  • Page 21: Hastelloy (1050H) And Stainless Steel (1050S)

    Dimensions and Mounting Hastelloy (1050H) and Stainless Steel (1050S) ti14343b ti14344b ti14345b ti14542b 1 in. npt(f) or 1 in. bspt fluid inlet ports (4) 11.8 in. (300 mm) 1 in. npt(f) or 1 in. bspt fluid outlet ports 12.9 in. (328 mm) 13.7 in.
  • Page 22: Stainless Steel (1050S) With Center Flange Manifold

    Dimensions and Mounting Stainless steel (1050S) with center flange manifold ti29941a ti29942a 11.8 in. (300 mm) 14.9 in. (378 mm) 17.1/18.7 in. (434/475 mm) 11.5 in. (292 mm) 3.1 in. (79 mm) 7.35 in. (187 mm) 13.9 in. (353 mm) 15.0 in.
  • Page 23: Stainless Steel (1050S) With Center Tri-Clamp Manifold

    Dimensions and Mounting Stainless steel (1050S) with center tri-clamp manifold 11.8 in. (300 mm) 14.9 in. (378 mm) 15.9 in. (403 mm) 11.5 in. (292 mm) 3.1 in. (79 mm) 7.35 in. (187 mm) 13.9 in. (353 mm) 15.0 in. (381 mm) 3.8 in.
  • Page 24: Performance Charts

    Performance Charts Performance Charts Test Conditions: Pump tested in water with inlet submerged. Cycle Rate (0.83. 8.3) Fluid Pressure Operating Air Pressure (0.7, 7.0) (0.55, 5.5) 125 psi (0.83 MPa, 8.3 bar) (0.41, 4.1) 100 psi (0.7 MPa, 7.0 bar) (0.28, 2.8) 70 psi (0.48 MPa, 4.8 bar) (0.14, 1.4)
  • Page 25: Technical Specifications

    Technical Specifications Technical Specifications Maximum fluid working pressure ......125 psi (0.86 MPa, 8.6 bar) Air pressure operating range .
  • Page 26 Technical Specifications Non-wetted external parts Aluminum (1050A) aluminum, coated carbon steel Hastelloy (1050H) hastelloy, stainless steel, polypropylene or aluminum (if used in center section) Plastic (1050P, 1050C, and 1050F) stainless steel, polypropylene Stainless Steel (1050S) stainless steel, polypropylene or aluminum (if used in center section) Reference Information Maximum Storage Time (varies with conditions)
  • Page 27 Technical Specifications California Proposition 65 CALIFORNIA RESIDENTS WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov. 312877ZAD...
  • Page 28: Graco Standard Husky Pump Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of 12 months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

Table of Contents