. 2. Vent exhaust air
IG

Fluid Supply Line

See F
. 3 and F
. 4, pages 10 and 11.
IG
IG
1. Use grounded fluid supply lines (G). See
Grounding, page 7.
2. If the inlet fluid pressure to the pump is
more than 25% of the outlet working pres-
sure, the ball check valves will not close
fast enough, resulting in inefficient pump
operation.
3. At inlet fluid pressures greater than 15 psi
(0.1 MPa, 1 bar), diaphragm life will be
shortened.
4. For maximum suction lift (wet and dry), see
Technical Data, page 22.
312877A
A
D

Fluid Outlet Line

See F
1. Use grounded fluid hoses (L). See
Grounding, page 7.
2. Install a fluid drain valve (J) near the fluid
outlet.
3. Install a shutoff valve (K) in the fluid outlet
line.
Key:
A
Air supply line
B
Bleed-type master air valve
C
Air regulator
D
Air inlet
E
Master air valve (for accessories)
F
Air line filter
T
Muffler
U
U
Grounded air exhaust hose
V
Container for remote air exhaust
. 3 and F
. 4, pages 10 and 11.
IG
IG
Installation
V
T
ti14219a
9