Technical Data; Ben - Austro Flamm Ben User Instructions

Table of Contents

Advertisement

Available languages

Available languages

10.

Technical Data

10.1. Ben

Nominal thermal output (NWL)
Partial-load thermal output
Space heating capacity
Degree of effectivity
CO content at NWL
CO content at partial load
Flue gas temperature at NWL
Flue gas temperature at TL (partial load)
Flue gas mass flow rate at NWL
Flue gas mass flow rate at TL
Minimum delivery pressure at NWL
Minimum delivery pressure at TL
Capacity of filling tank
Min./max pellet consumption
Min./max autonomy
Air connector Ø
Flue connector Ø
Current at switch on
Current in operation
Voltage/current frequency
Dimensions
Weight
Minimum distance
Temperature limits
Relative humidity
81
Approx. 15 - 50 h
H x W x D
1000 x 500 x 531 mm
At side
At back
At front
Non-condensing
6.7 kW
2 kW
50 - 165 m³
90%
72.7 mg/Nm³
119.9 mg/Nm³
176 °C
97 °C
5.2 g/s
3 . 6 4 g / s
1 3 P a
1 1 P a
24 kg / 38 l
0.5 - 1.7 kg/h
80 mm
80 mm
300 W
25.6 W
230 V / 50 Hz
154 kg
100 mm
100 mm
800 mm
0 - 40°C
english