SURGICALL Y CLEAN AIR
AIR PURIFIER
OPERATIONAL MANUAL
Model No. SCA7000E
SURGICALLY CLEAN AIR
6300 Viscount Road Unit 1A
Mississauga Ontario Canada L4V 1H3
www.surgicallycleanair.com
info@surgicallycleanair.com
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCA7000E and is the answer not in the manual?

Questions and answers

Summary of Contents for Surgically Clean Air SCA7000E

  • Page 1 SURGICALL Y CLEAN AIR AIR PURIFIER OPERATIONAL MANUAL Model No. SCA7000E SURGICALLY CLEAN AIR 6300 Viscount Road Unit 1A Mississauga Ontario Canada L4V 1H3 WARNING: www.surgicallycleanair.com info@surgicallycleanair.com • Before operating the system, please read this manual thoroughly, and retain it for future reference.
  • Page 2: Table Of Contents

    CONTENTS FOR CUSTOMER ASSISTANCE CONSUMER LIMITED WARRANTY Chapter 1 IMPORTANT SAFETY E-6~10 PRECAUTIONS Chapter 2 HOW IT WORKS E-11 E-12 Chapter 3 PART NUMBER AND NAME Chapter 4 FEATURES AND SPECIFICATIONS E-13 Features E-13 Product Specifications E-13 Chapter 5 OPERATION E-14~15 Button Operation E-14...
  • Page 3: For Customer Assistance

    FOR CUSTOMER If you have questions about your air purifier, call the customer service number. Before calling, please note the model and serial number located ASSISTANCE on the back of the unit and fill in the following information below. This information will help us answer your questions much more quickly.
  • Page 4: Consumer Limited Warranty

    CONSUMER LIMITED WARRANTY Congratulations on your investment Surgically Clean Air (Hereinafter called SCA) gives you the following limited warranty for this product only if it was originally purchased from SCA or from an authorized dealer. SCA warrants that this product is free, under normal use and maintenance, from any defects in material and workmanship.
  • Page 5: Important Safety Precautions

    Chapter 1 TO REDUCE THE RISK OF ELECTRICAL SHOCK, FIRE OR INJURY TO PERSON(S) READ THE FOLLOWING: IMPORTANT SAFETY • Use only as described in this manual. PRECAUTIONS • Use only a 120-volt outlet with grounding wire receptacle. • Do not use the air purifier if the power cord or plug is damaged or the connection to the wall outlet is loose.
  • Page 6 Chapter 1 This manual classifies precautions into WARNINGS and CAUTIONS. Be sure to follow all precautions below: They are important for ensuring your safety. IMPORTANT SAFETY PRECAUTIONS 1. This unit cannot be used in an atmosphere containing explosive dust, gas or in an area where flammable WARNING substances are present.
  • Page 7 Chapter 1 IMPORTANT SAFETY PRECAUTIONS 4. DO NOT wash or reuse the VOC filter or clean the WARNING filter with liquid, especially alcohol, gasoline, paint If you do not follow these thinner, etc.. It may cause instructions exactly, the fire! unit may cause property damage, personal injury or loss of life.
  • Page 8 Chapter 1 IMPORTANT SAFETY PRECAUTIONS 7. Do not disassemble or modify this equipment. Unwarranted tampering can WARNING lead to fire, electric shock If you do not follow these and unit malfunction. instructions exactly, the unit may cause property damage, personal injury or loss of life.
  • Page 9 Chapter 1 IMPORTANT SAFETY PRECAUTIONS 10. Be careful not to tip over the unit when opening the front panel or moving it. If WARNING not, It may cause personal injury. If you do not follow these instructions exactly, the unit may cause property damage, personal injury or loss of life.
  • Page 10: How It Works

    Chapter 2 The air purifier functions as an air cleaner by helping to disinfect airborne microorganisms and removing particulates from the air. The centrifugal fans of the unit draw air through the front panel (Intake) HOW IT WORKS on the front of the unit. Then it passes through the Pre-filter, the Electronic cell, the VOC filter and the UV-Photo catalytic sterilization chamber.
  • Page 11: Chapter 3 Part Number And Name

    Chapter 3 PART NUMBER AND NAME 121301 111308 PART NUMBER 131309 131003 121303 111305 130001 111302 120214 131301 111217 130006 111216 131302 111303 131303 111314 111322 111313 130109 131313 131314 111301 181101 111321 130013 130028 121302 21301 111315 21101 151302 111304 111304 Front panel 131003 Sensors mode...
  • Page 12: Chapter 4 Features And Specifications

    Chapter 4 FEATURES Multi-Stage Filters FEATURES AND SPECIFICATIONS The unit utilizes a two-stage electrostatic precipitator (Electronic cell) combined with a Pre-filter (For large particles), an VOC filter (For odors and gases), UV germicidal light (Killing airborne pathogen), a Photo catalytic filter (Removes VOC's) and a Negative ion generator. Features Automatic Function The odor and particle sensor can let the unit automatically select the...
  • Page 13: Chapter 5 Operation

    Chapter 5 BUTTONS OPERATION Button Operation Helpful Hints RESET Button . POWER Button • After cleaning the Electronic Turns the purifier On and Off. cell, hold the SPEED button down 2 seconds to reset the SPEED Button cell cleaning time with When the SPEED button is pressed the airflow rate changes as shown beeping sound.
  • Page 14: Display Indicator Lights

    Connect the Power Chapter 5 Plug the unit into an electric outlet, the unit will be ready to run and the Power indicator on the display panel will light up. OPERATION Display Indicator Lights PM2.5 TVOC SPEED indicator light When the power is on, the “ L ” light will light up, select the speed by pressing the SPEED button.
  • Page 15: Remote Control Operation

    Chapter 5 The battery is already set in the remote control, pull out the clear sheet from the battery cover before using. OPERATION Remote Control Operation POWER RESET SPEED TIMER POWER RESET SPEED TIMER UV LMAP NEG.ION UV LMAP NEG.ION AUTO NIGHT AUTO...
  • Page 16: Chapter 6 Care And Maintenance

    Chapter 6 To maintain optimum performance of this air purifier, please clean the unit including the Pre-filter and Electronic cell periodically. When cleaning the unit, be sure to unplug the power cord, and never handle CARE AND MAINTENANCE the plug with wet hands. If so, electrical shock and bodily injury may occur as a result.
  • Page 17: 6-4 Cleaning The Electronic Cell

    Chapter 6 Cleaning the Electronic Cell To assure optimum performance the cell should be cleaned every one CARE AND MAINTENANCE to two months. Remove the Electronic Cell Stop the operation and unplug the unit. WARNING: • DO NOT clean the cell with alcohol, gasoline, paint thinner or other flammable substances.
  • Page 18: Replacing The Filter

    Chapter 6 Replacing the Filter When the “ ”indicator light on the control panel flash, the VOC filter CARE AND MAINTENANCE needs to be replaced. Replacing the VOC Filter Note: Remove plastic packaging Stop the operation and unplug the unit. from the VOC filter before operation.
  • Page 19: Chapter 7 Frequently Asked Questions

    CHAPTER 7 FREQUENTLY ASKED Why does my air purifier spark? QUESTIONS It is common for the purifier to occasionally spark, crackle or pop during operation. A spark indicates that the air purifier captured a large air particle. If the unit sparks continuously: •...
  • Page 20: Troubleshooting

    Chapter 8 TROUBLE SHOOTING Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing the following guide. All other servicing should be done by a SCA authorized service center. Power failure? Check other electrical appliances.
  • Page 21: Chapter 9 Wiring Diagram

    Chapter 9 WIRING DIAGRAM Sensors Module DISPLAY CIRCUIT BOARD CN_ION Negative ion generator CN_err CN_IN2 CN_C Red(+) Black(-) Grey Bule MAIN CIRCUIT BOARD Orange White PM2.5 Display Board Yellow CN_UV CN_EF CN_AC Fan motor CN_FAN White Interlock switch AC110V/60Hz Electronic cell Fuse Black White...
  • Page 22: Service Reminder Schedule

    SERVICE REMINDER SCHEDULE Pre-filter Wash Reminder Year Memo: Electronic Cell Wash Reminder Year Memo: E-23...
  • Page 23 SURGICALL Y CLEAN AIR 6300 Viscount Road Unit 1A Mississauga Ontario Canada L4V 1H3 Tel: 1-877-440-7770 www.surgicallycleanair.com info@surgicallycleanair.com SCA reserves the right to revise or modify products and/or specifications without notice. The contents of this manual are subject to change without notice. Ver.