When 'REPLACE UV LAMPS' indicator
light comes on
1
Turn 'POWER' button off
2
Remove the Front Panel,
Electronic Cell & Carbon Filter
A
Remove the front panel
B
Place fingers under each pull handle on
the top le and right sides of the electronic
cell holder and pull forward, evenly and
firmly, to dislodge the magnetic bracket
holders and tip the holder open
C
Pull out the carbon filter from behind the
electronic cell using the green tab on the
right hand side
3

Remove the Old UV-C Bulbs

A
Remove the 2 (two) silver bulb covers
B
Remove the 2 (two) UV-C bulbs by
rotating them slightly and pulling them
from the light sockets
C
Discard the old UV-C bulbs in regular
waste disposal
How to Change the UV-C Bulbs
Carbon Granite
SCA4000R
(
REPLACE
UV LAMPS
A
A
)
POWER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Carbon Granite and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Surgically Clean Air Carbon Granite

  • Page 1 How to Change the UV-C Bulbs Carbon Granite SCA4000R When ‘REPLACE UV LAMPS’ indicator POWER light comes on REPLACE Turn ‘POWER’ button off UV LAMPS Remove the Front Panel, Electronic Cell & Carbon Filter Remove the front panel Place fingers under each pull handle on...
  • Page 2 How to Change the UV-C Bulbs Carbon Granite SCA4000R Install the New UV-C Bulbs Remove the 2 (two) new UV-C bulbs from their packaging and hold by the ends (try not to touch the glass tubes) Insert 1 (one) UV-C bulb into each light socket...

This manual is also suitable for:

Sca4000r

Table of Contents