CONTROLLER SPECIFICATIONS AND REQUIREMENTS

Outlet configurations

5-2
XEROX DOCUPRINT NETWORK PRINTER SERIES INSTALLATION PLANNING GUIDE FOR MODELS 96/4635/180 NPS
This section discusses specifications for system outlets and the
required wall outlet configurations for the USA / Canada and
internationally.
Note: All power outlets must be dedicated to this equipment. When
determining the electrical connections for your printing system, make
sure that:
Each power cord has a separate circuit.
The printer power cord configurations match your receptacle.
Your electrical outlets are within the required specifications.
50 Hz systems: Ensure that power connections are per local codes/
regulations.
The following figure shows a 60 Hz American and Canadian wall
outlet in which to plug the printer controller.
Figure 5-1.
60 Hz wall outlet
1
3
1
AC Hot (ACH)
2
AC Hot (ACH)
3
Earth Ground (GND)
The required American and Canadian wall outlet voltage is 100 to
120 VAC between AC hot and neutral, and between AC hot and GND.
The voltage is less than three VAC between GND and neutral.
Refer to the 60 Hz and 50 Hz controller electrical requirements tables
earlier in this chapter for a description of the power specifications for
the controller.
Warning: To reduce the risk of electrical shock, do not plug
!
components into any other type of power system. Contract your
facilities manager or a qualified electrician if you are not sure what
type of power is supplied to your work area.