Ten-Tec RX-340 Technical Manual page 83

Hf dsp receiver
Table of Contents

Advertisement

B. Configure Memory-Scan; Channel to Channel with Lockouts.
*C4ccc
Start Channel for MScan: Range 0-100 (example: *C4020 for channel 20).
*C5ccc
Stop Channel for MScan: Range 0-100 (example: *C5040 for channel 40).
*CSccc
Skip Channel in MScan: (example: *CS030 for channel 30).
*CUccc
Include Channel in MScan: (example: *CU060 for channel 60).
*CEccc
Delete Memory by number. Use *TM to get list of memories. (*CE050)
C. Common Scanning Time Control Functions
*C3dd.dd
Set Dwell Time in seconds (example: *C301.00 or 1 second).
*C6
Reserved for future use.
*C7dd.dd
Set Dead Time in seconds--Default to 8 seconds.
*C8dd.dd
Set Gaze Time in seconds (example *C800.50 for 0.5 second)
D. Scanning Control Functions
*CP
Pause if scan running. Ignore if scan not active.
*CG
Continue if dwelling or paused.
*CF
Start PScan. Ignore if already scanning or if F1 is greater than F2.
*CM
Start MScan. Ignore if already scanning or if C start is greater than C stop.
*CX
Stop scanning and return to manual mode. Ignore if not scanning.
E. Scanning Query Functions
*TS
Request scan status.
Returns single *TSbXsss
'b' is a single decimal number containing bit-encoded status information:
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
*TA
Report all PScan Lockouts. No response if lockout list is empty.
*TM
Report all active memory channels. '5' appended if channel is skipped. No
response if empty.
*TD
Report lockout by number. Use *TA to get complete lockout list. No
response if lockout empty.
*TR
Report memory by number. Use *TM to get complete memory list. No
response if empty.
*TC
Report all Scan settings except Lockouts and contents of memory channels.
*TL
Tell last lockout number.
*TF
Tell number of free Lockouts.
*CK
Kill all Lockouts.
TIff.ffffff
Tell if specified frequency is in a Lockout.
Set if Scan is in Dwell-Time cycle.
Set if Dwell is set to infinite (Dwell time set to zero)
Set if Squelch is open (channel is active).
Set if running MScan. Cleared if running PScan.
Set if Scan (MScan or PScan) is active. Cleared otherwise.
Set if Scan is in Dead-Time cycle.
Set if Scan is in Gaze-Time cycle.
Set if Scan is in Pause state.
5-13

Advertisement

Table of Contents
loading

Table of Contents