for three seconds, and then returns to its previous display. The new Lockout Frequency
will be skipped in subsequent scan passes. If there are no empty Lockout locations
available, the display reads:
for three seconds, and then returns to its previous display. A new Lockout with a Center
Frequency identical to an existing Lockout overwrites the existing Lockout and does not
require an additional memory location. Scan Setup mode may be entered to delete an
existing Lockout and make room for the new one, if desired.
Similarly, to quickly change a channel from include to skip status, push the Lockout
button during a Paused MScan. Channel may be toggled while in scroll mode by
pressing the Lockout button. 'L' appears in the display to indicate a locked-out channel.
The Memory/Scan display reads:
for three seconds, where XX and YY...relate to the paused channel. The channel will be
skipped in subsequent scan passes. Editing is restricted to the Paused Channel.
If the Lockout button is pushed during an actively scanning (or dwelling) scan, the
Memory/Scan display reads:
for three seconds, and then returns to its previous display. In this case, the scan is
suspended at the present frequency for three additional seconds to allow the operator time
to Pause the scan, if desired.