Ten-Tec RX-340 Technical Manual page 76

Hf dsp receiver
Table of Contents

Advertisement

COMMAND DESCRIPTION
Kn
PRE-AMP/ATTENUATOR
Allows control of Preamp and Attenuator
'K1' Normal - Preamp OFF, attenuator OFF
'K2' Preamp on, attenuator OFF
'K3' Attenuator on, preamp OFF
Mn
AGC OPERATING MODE
Selects the AGC operating mode. 'F', 'M', 'S', and 'P' are
displayed in front of AGC setting on front panel. Where 'n' is one
of the following:
'M1'
'M2'
'M3'
'M4'
Note: The receiver will accept and execute a manual gain 'A'
command in any of the AGC modes.
PROGRAMMABLE AGC MODE SETTINGS
Note: Receiver accepts new parameters for Programmable AGC at
any time, but uses them only in Programmable mode (M4).
MA
Example:
MD
MH
#
FastAGC
Medium AGC
Slow AGC
Programmable AGC
Set Attack Rate in dB/mS.
'MA0.40' Program for 0.4 dB/mS
Program Decay Rate in dB/sec.
Program Hang Time in seconds.
Dump AGC state and restart AGC process.
5-6
VALID RANGE
1 - 3
1 - 4
Range:
00.01 to 01.00
Range:
00.01 to 99.99
Range:
00.01 to 99.99