Ten-Tec RX-340 Technical Manual page 80

Hf dsp receiver
Table of Contents

Advertisement

G
REPORT STATUS
Receiver responds with all operating parameters relevant to the current
operating mode. Parameters that are OFF, or are not relevant to the current
mode, will not be included in the response. See, also, command 'J'.
Command:
Response
Tx(xxx)
REPORT SPECIFIC STATUS
The receiver responds with the operating data, as specified, prefaced by the
command.
Example 1: (single request)
Command:
Response:
For:
Example 2: (multiple requests)
Command:
Response:
For:
X
REPORT SIGNAL LEVEL
This command requests signal level (or S-meter reading). Range is 0-150
covering the 150-dN dynamic range of the receiver (-140 to +10 dBm).
Example:
Command:
Response:
For:
V
REPORT FIRMWARE REVISION NUMBER
The receiver will respond with a number indicating the revision level of the
firmware.
Example:
Command:
Response:
For:
J
REPORT ALL OPERATING PARAMETERS
The receiver responds with all operating parameters regardless of their
current use or relation to the current operating modes. See command 'G' for
additional information.
'G'
'F15.010000D2B-1800'...etc...<CR>
'TF ' - Request receiver operating frequency.
'F15.0100000' <CR>
frequency=15.01 MHz
'TFBNX'- Request operating frequency, BFO offset,
notch-filter setting, and current S-meter level.
'F15.0100000B-00N0.00X020'<CR>
frequency = 15.01 MHz
BFO = -1800 Hz
Notch = 0.00 Hz (OFF Position)
S-meter = 20 db Signal
'X'-Request S-meter reading.
'X015'
S-meter= -125dBm signal level.
'V' - Request firmware revision number.
'V1 .90'
Firmware revision number of 1.90
5-10