Invert Power Derating Vs. Ambient Temperature; Prosine Charger Output Current Vs. Ac Input Voltage - Xantrex PROsine 2.0 User Manual

Inverter/charger
Hide thumbs Also See for PROsine 2.0:
Table of Contents

Advertisement

Specifications

Invert Power Derating vs. Ambient Temperature

PROsine Charger Output Current vs. AC Input Voltage

A–6
If the unit is in elevated ambient temperature above 40°C, you are required to
reduce power draw according to the following chart to maintain regulatory
compliance and to avoid over-temperature shutdown.
Inverter Output Power vs. Ambient
2500
2000
1500
1000
500
0
-40
When the PROsine is charging batteries from a weak shorepower source the AC
voltage may fall as the PROsine draws current. To reduce the chance of the
shorepower voltage collapsing below the configured transfer level the PROsine
will reduce the charging current at low shorepower voltage according to the
following graph:
Max Charge Current vs. Input AC Voltage
120
100
80
60
40
20
0
Low Vac
Shutdow n
Low Vac
Level
Shutdow n + 2V
Temperature
Unit may shutdown in this area
Unit will run
Unit will run in
in this area
this area
-20
0
20
Ambient Temperature (°C)
Low Vac
Shutdow n + 6V
Input Vac (V rms)
40
60
80
135Vac
445-0089-01-01

Advertisement

Table of Contents
loading