NOTES:
The receiver-to-transmitter serial communications and remote power capabilities
available with certain MTP models are not supported by this matrix switcher.
For best results, use a cable length of at least 50 feet (15 m) between the TP inputs
and outputs and the transmitter and receiver.
The switcher inputs and outputs TP signals on RJ-45 connectors.
Three, four, or six (depending on the matrix size) 15-pin HD and 5-pole 3.5 mm direct
insertion input connectors are available for direct RGB (VGA) and stereo audio inputs
without an MTP transmitter.
NOTE: For most switchers, the available local inputs parallel the TP input of the same
number and either input can be used.
For the MTPX Plus 128, four inputs are local only and eight inputs are TP only.
Two, four, or eight (depending on the matrix size) 5-pole 3.5 mm captive screw ports are
available for direct mono audio outputs to an audio device without an MTP transmitter.
One or two (depending on the matrix size) 15-pin HD output connectors are available for
direct RGB (VGA) output to a video device without an MTP receiver.
NOTE:
The direct input and direct output connectors can also support HD-YUV video, YUV
video, S-video, and composite video.
For low resolution MTPs (S-video and composite video) on the TP inputs and
outputs, the MTPX Plus audio circuits are compatible only with the newer
generation, mono audio models. See the MTP transmitter/receiver manual to
determine which MTP models you have.
There are 4, 8, or 16 (depending on the matrix size) 3-pole 3.5 mm captive screw ports for
bidirectional RS-232 signal inserts. These signals, from a dedicated source (rather than from
the selected input), can be directly inserted into the signal set routed to the TP output.
The matrix switcher can be remotely controlled via an Ethernet LAN port, serial port, or USB
port (MTPX Plus 128 only) connection using either the Windows®-based Extron Matrix
Switchers Control Program or the Simple Instruction Set (SIS).