Table 2-6 Functional Outline of Line/Trunk Circuit Cards (Continued)
FUNCTIONAL
CARD NAME
NAME
PN-8LCS
PN-M03
PN-2ODTA
PN-PW00
PN-8RSTA
PN-TNTA
PZ-VM00
PZ-VM01
4VMEXT
Note:
The cable length between the DLC and terminal varies depending on the type of terminal. For the line conditions
each terminal, refer to
TERMINAL TYPE
DTP-8-1
DTP-8D-1
CHAPTER 2
Page 14
Revision 2.0
LC
8-line Analog Line Circuit Card for single-line telephones
Loop resistance: Max. 600 Ω
This card is equipped with a controller for momentary open function.
M03
V.35 DTE Interface Card
This card is used together with the PN-2DPCB card to provide the V.35 interface.
ODT
2-line OD Trunk Card
This card can be used as either a 2-wire E&M trunk or a 4-wire E&M trunk, and is
internally equipped with a –48 V DC On-Board Power Supply.
Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one card.
PWR
Provides -48V power for one DeskCon or two zone transceivers; maximum is 3 per
system; uses two card slots
PBR
8-line DTMF Receiver Card
This card can be used for a DTMF station line, DID or tie line.
TNT
2-line Tone/Music Source interface Card
This card is used for BGM or Music on Hold, and is equipped with two interface for an
external tone/music source.
4VM
4-Port Voice Mail Card (NEAX Mail AD-8)
4-Port Expansion Card for AD-8 (VM00)
Table 2-7
.
Table 2-7 Line Condition of Each Terminals
CARD TYPE
PN-8DLCJ / 8DLCP
(STANDARD)
PN-4DLCD / 4DLCQ
(STANDARD)
PN-2DLCB / 2DLCN
(LONG)
PN-8DLCJ / 8DLCP
(STANDARD)
PN-4DLCD / 4DLCQ
(STANDARD)
PN-2DLCB / 2DLCN
(LONG)
FUNCTIONAL OUTLINE
CABLE LENGTH
(Cable 24AWG)
984ft. (300m)
984ft. (300m)
[3937ft. (1200m)]
2788ft. (850m)
[3937ft. (1200m)]
984ft. (300m)
984ft. (300m)
[3937ft. (1200m)]
2788ft. (850m)
[3937ft. (1200m)]
NDA-24219
REMARKS
Note 1
Note 1