3. FUNCTIONAL OUTLINE OF EQUIPMENT
This section explains the functional outline of the equipment (modules, installation hardware, circuit cards) used in
the PBX.
3.1
Functional Outline of Modules
Table 2-2
shows the functional outline of the modules.
MODULES
SN1420 PIMAB-A
3.2
Functional Outline of Installation Hardware
Table 2-3
shows the functional outline of installation hardware.
INSTALLATION
HARDWARE
COVER PARTS
19" BRACKET
Table 2-2 Functional Outline of Modules
FUNCTIONAL
NAME
PIM
Port Interface Module (PIM)
A PIM provides 10 card slots for common control, Line/Trunk, and
Application Processor (AP) cards. It also houses a AC/DC Power Supply
and batteries for protection from short-term power interruption (standard).
Two champ connectors for line/trunk (LTC0 to 1) and a connector for Power
(PWR) are located at the lower front side of the PIM.
A PIM provides a maximum of 9 card slots for line/trunk (LT) cards. At
maximum configuration, the system is comprised of 2 PIMs and it provides
88 physical ports (48 ports x 2) to MDF (PIM0 Slot LT8/AP4 used for PN-
BS00).
Table 2-3 Functional Outline of Installation Hardware
FUNCTIONAL
NAME
TOP
Bottom Cover (includes Top Cover)
BOTTOM
This hardware (bottom cover and top cover) is used for all NEAX1000
COVER
installations. A 4-rubber foot is required for desktop installation with PIM.
19"
19-inch Bracket
BRACKET
The 19-inch bracket is sets of hardware to mount the PIM in IEC standard 19-
inch rack. One set of 19-inch bracket is required for PIM.
FUNCTIONAL OUTLINE
FUNCTIONAL OUTLINE
NDA-24219
CHAPTER 2
Page 9
Revision 2.0