NEC NEAX2000 IVS Series System Manual page 135

Very small platform
Table of Contents

Advertisement

NAP-200-010
Sheet 4/7
System Initialization and
System Data Entry
(1) Programming Procedure for Music On Hold
For providing Hold Tone Source on the MP card:
START
CM08
Select the music to be provided.
Define the type of call to be provided with Hold Tone
CM48
on the MP card.
Note:
END
For providing External Hold Tone Source through the MP card:
START
CM48
Define the type of call to be provided with Hold
Tone.
END
DESCRIPTION
When using the MP card, set the JP1
switch to UP (Internal Hold Tone Source).
DESCRIPTION
(3) 183
(4) 0: Nocturne
1 : Minuet
.
Y = 0
(1) 00: C.O. Line Call
01: Tie Line Call
02: Internal Call
(2) 1400: Hold Tone Source on MP card
.
Y = 0
(1) 00: C.O. Line Call
01: Tie Line Call
02: Internal Call
(2) 1400: Hold Tone Source through MP card
NDA-24219
DATA
DATA
CHAPTER 3
Page 121
Revision 2.0