NAP-200-007
Sheet 46/55
Termination of Cables on MDF
Connect the 25-pair cables on the MDF referring
STEP 3:
•
Figure 007-35
(No. 0 - No. 7).
26 Sta. T0
27 4LC. T0
28 C.O. T0
29 4COT. T0 4
30 Sta. T1
31 4LC. T1
32 C.O. T1
33 4COT. T1 8
34 Sta. T2
35 4LC. T2
36 C.O. T2
37 4COT. T2 12 4COT. R2
38 Sta. T3
39 4LC. T3
40 C.O. T3
41 4COT. T3 16 4COT. R3
42 Sta. T4
43 4LC. T4
44 C.O. T4
45 4COT. T4 20 4COT. R4
46 Sta. T5
47 4LC. T5
48 C.O. T5
49 4COT. T5 24 4COT. R5
50
Note:
Pin 23 on PFT1 is MJ alarm input from LTC0 pin 25. This is also used when NEAX1000 is set up as
Remote PIM.
shows the PFT connector pin assignment for each PFT circuit number
PFT0
PFT0
1
Sta. R0
2
4LC. R0
No. 0
3
C.O. R0
4COT. R0
5
Sta. R1
6
4LC. R1
No. 1
7
C.O. R1
4COT. R1
9
Sta. R2
10 4LC. R2
No. 2
11 C.O. R2
13 Sta. R3
14 4LC. R3
No. 3
15 C.O. R3
17 Sta. R4
18 4LC. R4
No. 4
19 C.O. R4
21 Sta. R5
22 4LC. R5
No. 5
23 C.O. R5
25
Figure 007-35 PFT Connector Pin Assignment
Figure 006-34
PZ-8PFTA
26 Sta. T6
27 4LC. T6
28 C.O. T6
29 4COT. T6 4
30 Sta. T7
31 4LC. T7
32 C.O. T7
33 4COT. T7 8
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49 E
50 –27V
NDA-24219
and
Figure
006-35.
PFT1
PFT1
1
Sta. R6
2
4LC. R6
No. 6
3
C.O. R6
4COT. R6
5
Sta. R7
6
4LC. R7
No. 7
7
C.O. R7
4COT. R7
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Note
24
25
CHAPTER 3
Page 95
Revision 2.0