schmersal PSC1 Installation Manual page 38

Field buses
Hide thumbs Also See for PSC1:
Table of Contents

Advertisement

Installation manual
The following device categories are defined:
Hex: 30
CSS 34, Safety sensor
Hex: 31
AZM 200, Solenoid interlock „Z"-variant
Hex: 32
MZM 100, Solenoid interlock „Z"-variant
Hex: 33
AZ 200, Safety sensor
Hex: 34
CSS 30S, Safety sensor
Hex: 35
MZM 100 B, Solenoid interlock „B"-variant
Hex: 36
AZM 300B, Solenoid interlock „B"-variant
Hex: 37
RSS 36, Safety sensor
Hex: 38
AZM 300Z, Solenoid interlock „Z"-variant
Hex: 39
RSS 16, Safety sensor
Hex: 3A
RSS 260, Safety sensor
Hex: 3D
MZM 120 B, Solenoid interlock „B"-variant
Hex: 3E
MZM 120 BM, Solenoid interlock „B"-variant
Hex: 3F
AZM 201Z, Solenoid interlock „Z"-variant
Hex: 40
AZM 201B, Solenoid interlock „B"-variant
Hex: 41
Operator panel BDF200-SD
Hex: 43
AZ 201, Safety sensor
The individual bits in the diagnostic byte for the SD-Gateway have the following meaning:
BIT
Error
Bit 0
Failure SD-Interface
Bit 1
Bit 2
Bit 3
Bit 4
SD initialisation error
Bit 5
SD Teach error
Bit 6
SD short circuit
Bit 7
SD communication error
Table 20: SD Master Diagnose, SD System error / Content Response byte 00, Diagnostic byte Gateway
Installation manual PSC1-Field buses V2.2.docx
Description
SD Interface centralized alarm, message 1 sec. delayed,
invalid SD data.
Reinitialisation of the SD chain required! Shut down
operating voltage of the gateway and SD Slaves. Possibly
no SD slave connected!
SD chain structure has changed after Power On! If OK,
operate TEACH.
Bit 6 SD short circuit Short-circuit in the SD interface wires.
Switch off and eliminate error.
One or more SD slaves unavailable. Invalid data from the
SD slaves.
If necessary, check SD installation.
Page 38 of 166