schmersal AES 2285 Operating Instructions Manual

Safety-monitoring module

Advertisement

Quick Links

Operating instructions
Safety-monitoring module
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.2 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
AES 2285
1

Advertisement

Table of Contents
loading

Summary of Contents for schmersal AES 2285

  • Page 1: Table Of Contents

    5.1 Operating principle after the operating voltage is switched on ..3 Further technical information can be found in the Schmersal 5.2 LED functions......... .3 catalogues or in the online catalogue on the Internet: www.schmersal.net.
  • Page 2: Warning About Misuse

    Up to 6 safety Rated impulse withstand voltage U 4 kV guards can be monitored by means of the AES 2285 safety-monitoring Thermal test current I module. Fuse rating for the operating voltage: F1: internal electronic trip, tripping current >...
  • Page 3: Safety Classification

    Operating instructions Safety-monitoring module AES 2285 5. Operating principle and settings Switching capacity of the safety contacts: 13-14 / 23-24: max. 250 V, 6 A ohmic (inductive in case of 5.1 Operating principle after the operating voltage is switched on...
  • Page 4: Set-Up And Maintenance

    Operating instructions Safety-monitoring module AES 2285 6. Set-up and maintenance 7. Disassembly and disposal 6.1 Functional testing 7.1 Disassembly The safety function of the safety-monitoring module must be tested. The safety-monitoring module must be disassembled in a de-energised The following conditions must be previously checked and met: condition only.
  • Page 5: Start Configuration

    • Cross-wire shorts between the control circuits are detected. • When the AES 2285 safety-monitoring module is used with the • Category 3 – PL d to ISO 13849-1 possible. operating mode "Automatic start", an automatic restart after a...
  • Page 6: Actuator Configuration

    Operating instructions Safety-monitoring module AES 2285 8.4 Actuator configuration 8.5 Pin configuration (depending on the number of doors) (Unused sensor inputs must be accordingly bridged) Single-channel control (see Fig. 6) • Suitable for increase in capacity or number of contacts by means of Number of sensors to be monitored: 1 contactors or relays with positive-guided contacts.
  • Page 7 Safety-monitoring module AES 2285 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
  • Page 8 K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone: +49 - (0)2 02 - 64 74 - 0 Telefax: +49 - (0)2 02 - 64 74 - 1 00 E-Mail: info@schmersal.com...

Table of Contents