Consumption profile (Advanced version only)
6 registers for monitoring total time the meter has operated in different flow intervals.
Registered intervals are freely selectable as % of Qn (Q3).
Tariff (Advanced version only)
6 tariff registers count the volume delivered within the selected tariff windows, based on time of
day, flow rates, or a combination.
Tariff can also be used for consumption profile where consumption is related to different time
intervals or flow rates.
Tariff values visible on the display.
Settling date (Advanced version only)
At midnight (23:59:59) on a predefined date the totalizer 1 index value is stored. Old values are
stored to show the latest two totalized 1 index values. Settling values are visible on the display.
Statistic (Advanced version only)
The statistic feature delivers water consumption information to inspect the consumption limits
of the installation. The real values are first available after the period is finished. A reset function
clears the values and new values are ready after next period. Until the new measured values
are available, minimum values are set to maximum value and vice versa, the rest is set to zero.
● Min. flow rate with time and date registration
● Max. flow rate with time and date registration
● Min. daily consumption with date registration
● Max. daily consumption with date registration
● Latest 7 days' total and daily consumption
● Actual month's consumption
● Latest month's consumption
SITRANS FM MAG 8000
Operating Instructions, 03/2020, A5E03071515-AH
Features