Mitsubishi Electric M Series Manual page 285

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M series
MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA
Indoor unit failure mode table
NOTE:Blinking patterns of this mode differs from the ones of Troubleshooting check table.
Left lamp of
Right lamp of
OPERATION
OPERATION
INDICATOR lamp
INDICATOR lamp
Not lighted
Not lighted
1-time flash
Not lighted
every 0.5-second
2-time flash
Not lighted
2.5-second OFF
3-time flash
Not lighted
2.5-second OFF
5-time flash
Not lighted
2.5-second OFF
11-time flash
Not lighted
2.5-second OFF
12-time flash
Not lighted
2.5-second OFF
13-time flash
Not lighted
2.5-second OFF
Abnormal point
(Failure mode)
Normal
When the room temperature thermistor
Room temperature
short or open circuit is detected every 8
thermistor
seconds during operation.
When the indoor coil thermistor short or
Indoor coil thermistor
open circuit is detected every 8 seconds
(Main 1, 2 and sub)
during operation.
When the serial signal from the outdoor unit is
Serial signal error
not received for a maximum of 6 minutes.
• Float sensor is open.
Drain pump
• Float sensor detects abnormal water level.
Float sensor
When the rotational frequency feedback
Indoor fan motor
signal is not emitted during 12-second the
indoor fan operation.
When it cannot be read properly data in the
nonvolatile memory of the indoor electronic
Indoor control system
control P.C. board.
When the indoor coil thermistor short or
Indoor coil thermistor
open circuit is detected every 8 seconds
(Main 3)
during operation.
CEILING CASSETTE Inverter Heat Pump
Condition
C-283

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents