Activating Emergency Mode - CEStronics CES OMEGA FLEX Manual

Signalling of the locking devices
Table of Contents

Advertisement

2   Signalling while using the master media

2.13 Activating emergency mode

Required master media:
Emergency-Key
l
The Emergency-Key must first be authorised for the locking device with which it is to be
used
Procedure:
1. Hold the locking media before the reading field of the locking device.
After ca. 1 second, the following signal appears:
1x short green and 1x short beep
If the locking device already lights up green while the Emergency-Key is being read, but no
green flashing signal appears after one second, emergency mode is already active.
2. Remove the Emergency-Key from the reading field of the locking device.
The locking device is now in emergency mode. Permanent access without locking media is now
possible because the coupling of the locking device is permanently engaged. The emergency mode
can be deactivated by Emergency-Key only.
Troubleshooting:
Signalling
The Emergency-Key could be read but is
not authorised for this locking device.
Signalling of OMEGA FLEX Locking devices
Reason
Authorise the Emergency-Key.
Solution