Signalling of the locking devices
Table of Contents

Advertisement

2.2 Authorising additional master media

All master media must be authorised prior to their first use. The only exceptions are the RF-Ini-
Master (in NET and VA devices) and the RF-Trace-Master.
Required master media:
System-Master
l
Any master media that needs to be authorised
l
Procedure:
1. Hold the System-Master for ca 1 second in the reading field of the locking device to start
the "authorise mode" of the locking device.
The following signal appears:
1x short green and 1x short beep
2. Now you can authorise any number of master media one after the other by holding each
master media for ca 1 second in the reading field of the locking device.
The following signal appears for each master media:
1x short green and 1x short beep
Page 10 of 39
2   Signalling while using the master media
Signalling of OMEGA FLEX Locking devices