CEStronics CES OMEGA FLEX Manual page 11

Signalling of the locking devices
Table of Contents

Advertisement

2   Signalling while using the master media
3. Hold the System-Master for ca 1 second in the reading field of the locking device to end the
"authorise mode.
The following signal appears:
1x long green and 1x long beep
The "authorise mode" will end automatically after 5 seconds. Die new authorisations
remain stored.
All master media, which were held before reading field, are now authorised to make settings for
this locking device.
Troubleshooting:
Signalling
During step 2:
The master media could be read but
could not be authorised:
a) You have tried to authorise a
Program-Master for a V-NET locking
device.
b) The master media has the wrong
system identity code
c) You have used a locking media
instead of a master-media.
d) you have tried to authorise an RF-
Trace-Master or an RF-Ini-Master.
Signalling of OMEGA FLEX Locking devices
Reason
a) Program-Master cannot be authorised
for V-NET devices.
b) Use a master media with the correct
system identification code.
c) Use a master media.
d) RF-Trace-Master and RF-Ini-Master
cannot be authorised.
Solution
Page 11 of 39

Advertisement

Table of Contents
loading

Table of Contents