JSXFA
q
Piping
Compression fitting type *
E
F
Direct piping type
*1 Seals and washers are included.
r
Fluid and ambient temperatures
B
−40 to 60°C
y
Pilot port size
Nil
1/4
1
1/8
Caution
Selection of Pilot Valve
For the pilot valve orifice diameter, ø5 mm or larger is
recommended.
When the pilot orifice diameter is ø3 mm or larger and less
than ø5 mm, put "A" to the end of the product number for
made-to-order. The product may not operate correctly if the
pilot valve orifice diameter is inadequate. (port size: 3/4, 1)
Depending on the pilot piping port size *
valve may not operate correctly.
*1 The I.D. of the pilot piping must be larger than the pilot valve
orifice diameter to use. The maximum pilot piping I.D. is 10 mm.
Pilot valve
Pilot piping
JSXFA
Port size:
3/4, 1
3
Pulse Valve
JSXFA
How to Order
E
06 R
B
q
w
e
r
w
IN/OUT port size
1
06
10
14
t
With/without silencer
Nil
Without
S
With
* Port size: 14 only
Select Nil for 06 and 10.
1
or length, the
Exhaust
Orifice diameter:
ø5 mm or larger
Pilot port
Valve for Dust Collector
Series
1
t y
Compression
fitting type
e
3/4 (20A)
1 (25A)
1 1/2 (40A)
Port size
06
10
14
V
V
V
—
—
V
Made to Order
Pilot valve orifice diameter: Special specification
A
For ø3 mm or larger and less than ø5 mm Port size: 06, 10
JSXFA
Enter the standard
product number.
Specifications
Series
Orifice diameter
Port size
Fluid
Min. operating pressure differential [MPa]
Max. operating pressure differential [MPa]
Max. system pressure
Fluid temperature
Ambient temperature
Compression fitting type
Weight
[g]
Direct piping type
*1 No condensation allowed
RoHS
Direct piping type
Thread type
R
Rc
N
NPT
F
G
Symbol
1
2
(IN)
(OUT)
A
B
JSXFA
06
10
[mm]
ø32
ø40
3/4
1
Air
0.1
0.9
[MPa]
0.9
−40 *
1
[°C]
to 60
[°C]
−40 to 60
470
910
290
500
14
ø50
1 1/2
1850
1230