Door And Frame Preparation; Mark Door; Drill Door; Install Strike - Assa Abloy Corbin Russwin CL3100 Series Installation Instructions Manual

Grade 1 key-in-lever
Table of Contents

Advertisement

Grade 1 Key-In-Lever VR Lever Lock
CL3100 Series
Installation Instructions
2

Door and Frame Preparation

a

Mark Door

• Fold door marker (FM347) on the door and mark the hole centers.
• Bore 2-1/8" hole.
• Bore 1" hole.
b

Drill Door

• Cut rectangular front recess.
c

Install Strike

• Mark recess for latch bolt.
• Mark outline of strike.
For Installation Assistance contact Corbin Russwin
1-888-607-5703 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2016, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Centerline of
Centerline of
front strike
front strike
Figure 4
Install Strike
38"
38"
Finished
Finished
High edge of
High edge of
floor
floor
beveled door
beveled door
Figure 2
Mark Door
1-1/8"
1-1/8"
2-1/4"
2-1/4"
Figure 3
Drill Door
• Cut recess for latch bolt.
• Install strike; secure with two (2) screws.
IMPORTANT
Dead locking plunger stops on strike when door is closed.
Strike
Strike
4
beveled door
Beveled door
2-1/8"
1"
1"
5/32" DEEP
5/32" Deep recess
RECESS
Desired backset
DESIRED BACKSET
Dead locking
Dead locking
plunger
plunger
FM345 01/19