S2-S1 Measurement Mode; General Operating Information; Signal Connections - Tektronix 7D12 Operator's Instruction Manual

A/d converter
Hide thumbs Also See for 7D12:
Table of Contents

Advertisement

M2 Operating Instructions-7D12 Operators
VOLTAG
READOU
E
T
L
-
VERTICA
DISPLAY
WAVEFOR M
ZERO
VOLTS
+
C
I
to· .
~
GATE
WAVEFOR
-
~
M
roo
...
I
TyF
SENSITIVI
(VOLTS
PER
DIVISION)
~V
SI
100, oS
I
....
'1
....
.... . ..
.... . ...
I
I
I
i
I
I
...
I"
. ... .... ....
V
I
I
(A) ZERO VOLT MEASUREMENT POINT
....
~oo
... s
_----4--+--4--+-----4--4
-i--+--t-----i
I
S1
......
. .............. T'
I
ZERO~~~~~~~~~~~~I~~~~+H~
VOLTS
1
I
T
I
1··
~.
I
V
(B) FOUR VOLT MEASUREMENT POINT
Fig. 3-2. S1 Mode Display and Readout (DC Coupled).
41. Adjust the time-base delay-time multiplier to posi-
tion the S1 measurement point directly under the positive
portion of the square wave.
42. The readout should read approx imately +4.00 V.
See Fig. 3-2B.
S2 -S1 Measurement Mode
43. Use the same setup procedure as described previ-
ously under S1 Measurement Mode, step 31.
44. Set the delaying time-base sweep rate to 200 micro-
seconds per division.
45. Set the MODE switch to OUT
~:2-S1'
and the
COUPLING switch to OUT DC.
46. Adjust the delay-time multiplier to p0sition the S1
measurement point directly under the vertic
3
·display wave-
form zero-volt level.
3-4
47. Adjust the time-base sweep rate to position the S2
measurement point directly under the vertical-display wave-
form four-volt level.
48. The readout should read approximately +4.00 V
(the difference voltage between the S1 and S2 measurement
points). See Fig. 3-3A.
49. Adjust the delay-time multiplier to position the S1
and S2 measurement points as shown in Fig. 3-3B.
50. The readout voltage should read approximately
-400 V.
GENERAL OPERATING INFORMATION
Signal Connections
M2 INPUT. In general, 50-ohm coaxial cables offer a
convenient means of connecting signals to the M2 INPUT;
however, the vertical sensitivity can be extended by a factor
of 10 by using the P6055 probe. See M2 Operation Using
P6055 Probe.
E
DIFFERENC
VOLTAGE
READOUT (S2 ·Sl)
+
~
I
00'
...
VERTICAL
DISPLAY
WAVEFORM
-
...
ZERO VO LTS
-
GATE
WAVEFOR
..
M
10'"
I -
I;,-F
SENSITIVITY
(VOL TS/DIVISIO
- .04
I
to·
10'"
I
99V
I
200, oS
I
I
I
f'
. ...
····1
...
. ...
I
I
1
I
I
I
j-
S l
_S2
·1··
. ..
. ...
i-!
~
1
(A) + POLARITY SYMBOL
DeV
roo,.s
I
I
'1'
!
:
I
I
I
I
SI
+I
~S2
'1'
I
r
~V
I
I
(B) - POLARITY SYMBOL
Fig. 3-3. S2-S1 Mode Display and Readout.
....
REV. C, SEPT. 1975