Troubleshooting
The table below indicates the most common problems that may arise during slicing and the necessary
remedies.
PROBLEM
The machine does not start when
the white or green button is
pressed
When the switch is turned or
when the white or green button is
pressed, the machine starts, but
the white functioning light is not on
The machine starts, but there are
vibrations. The motor is very hot
and there is a bad smell
Under strain, the machine slows
down or comes to a stop
Excessive resistance to product
slicing
The slices are ragged and/or
shaped irregularly
Unsatisfactory blade sharpening
The product tray does not slide
When the switch is turned or when
the black or red button is pressed,
the machine does not stop
DISMANTLING THE SLICER
These machines are made of the following elements:
•
Aluminium frame;
•
Stainless steel fittings and others;
•
Electrical parts and cords;
•
Electrical motor;
•
Plastic materials, etc.
Whether dismantling is entrusted to third parties or done in-house (in that last case you will have to separate
the various materials) please note that disposal of the materials can only be carried out by duly authorized
businesses. In any case, please comply to the current norms of your country.
POSSIBLE CAUSE
No power supply
The blade guard is not correctly
positioned
Defective electrical control circuit
Defective indicator
Defective motor or transmission
Defective transmission
The blade is blunt
The blade is blunt
The blade is excessively worn out
Worn wheels
Guides are insufficiently lubricated
Defective electrical control circuit
14
REMEDY
Ascertain that the plug is correctly
inserted
Check
Call technical assistance
Do not use the machine when the
pilot lamp is not on; Call technical
assistance
Do no use the machine, call
technical assistance
Call technical assistance
Sharpen the blade
Sharpen the blade
Call technical assistance
Replace the wheels; call technical
assistance
Lubricate
Stop the machine, unplug from
mains and call technical assistance
Need help?
Do you have a question about the MS-IT-0300-IP and is the answer not in the manual?