Data
Byte
Bit
Type
2
Integer
3
Integer
4
Integer
3A1704N
State or
Range
CGM Outputs to PLC Inputs for Monitoring Description
System Mode Select (Operating Mode): Monitor the various modes of the dispensing
system. CGM feedbacks the status of the system to the PLC. Night mode is only available
on standard HFRs with full circulation, or Semi-automatic circulation valves installed. If
using a manually controlled dispense valve (P2/ Fusion DV Option), shot and sequence
modes are not available.
1
DISABLED mode
2
STANDBY mode
3
SHOT mode
4
SEQUENCE mode
5
OPERATOR mode
6
N/A
7
NIGHT mode
Selected Shot/Sequence Position Number: In Shot Mode, monitors the Active Shot number.
In Sequence Mode, monitors the Active Sequence position number.
1-100
Shot mode
1-20
Sequence mode
Selected sequence: In Sequence mode, set the active sequence.
1-5
Active sequence
Available Internal Data
13