Graco 24J415 Instructions - Parts Manual page 18

Communications gateway module installation kit, for use with hfr systems to provide fieldbus communications abilities, for professional use only
Hide thumbs Also See for 24J415:
Table of Contents

Advertisement

Available Internal Data
Data
Byte
Bit
Type
0
1
2
3
13
4
5
6
7
14,
15,
Double
16,
Integer
17
18,
19,
Double
20,
Integer
21,
22,
Integer
23
24,
25,
Double
26,
Integer
27
28,
29,
Double
30,
Integer
31
18
State or
Range
CGM Outputs to PLC Inputs for Monitoring Description
Units and Operating Information: Rate Unit
0
Minute
1
Second
Units and Operating Information: Control Mode
0
Pressure
1
Flow
Units and Operating Information: Dispense Mode
32 (bits)
00 = Time
01 = Volume
10 = Weight
Not Used
0
N/A
1
N/A
Not Used
0
N/A
1
N/A
Not Used
0
N/A
1
N/A
Not Used
0
N/A
1
N/A
Flow Rate Set point: Integer value of the Flow rate set point in the dispensing system
The value from the CGM is an integer and must be multiplied by 0.0001 for the requested
flow rate to be in system units.
Example: Double word 14 = 291234 = 29.1234cc/sec (unit chosen is cc/sec)
Dispense Amount (Shot Size) Set point: Integer value of the Dispense amount set point in
the dispensing system.
The value from the CGM is an integer and must be multiplied by 0.001 for the requested
dispense amount to be in system units.
Example: Double word 18 = 5002499 = 5002.499cc (unit chosen is cc)
Ratio Set point: Integer value of the Red / Blue Material Ratio set point in the dispensing
system. Note this value is dependent on the pump sizes and does not vary.
The value from the CGM is an integer and must be multiplied by 0.01 for the requested ratio
to be in system units. xx.xx: 1 where xx.xx is Red and 1 is Blue
Example: Word 22 = 2400 = 24.00:1 (red pump = 120, blue pump = 5)
Red Pump Pressure Actual: Integer value of the actual Red pump pressure.
The value from the CGM is an integer and must be multiplied by 0.0001 for the actual pres-
sure to be in system units.
Example: Double word 12345678 = 1234.5678psi (unit chosen is psi)
Blue Pump Pressure Actual: Integer value of the actual Blue pump pressure.
The value from the CGM is an integer and must be multiplied by 0.0001 for the actual pres-
sure to be in system units.
Example: Double word 7561234 = 756.1234psi (unit chosen is psi)
3A1704N