Data
Byte
Bit
Type
0
1
2
3
4
12
Bit
5
6
7
3A1704N
State or
Range
CGM Outputs to PLC Inputs for Monitoring Description
Units and operating Information: Volume Units
10 (bits)
00 = Gallons
01 = cc's
10 = Liter
Units and operating Information: Weight Units
32 (bits)
00 = Grams
01 = Kilograms
10 = Pounds
Units and operating Information: Pressure Units
54 (bits)
00 = Bar
01 = psi
10 = Mpa
Units and operating Information: Temperature Units
0
Fahrenheit
1
Celsius
Units and operating Information: Flow Unit
0
Volume
1
Weight
Available Internal Data
17